Checks for Status Change You can define prerequisites for each status change that can occur for a force element, its material and personnel categories, and logistical requirements. The system checks these prerequisites when the relevant status is changed.
Example
A prerequisite for a status change can be the existence of a particular infotype, attribute, or assignment, for example.
If one or more prerequisites are not met, the system issues error, warning, or information messages accordingly.
Certain predefined checks are shipped with the standard system. You can also define your own checks.
You are familiar with the checks provided. They are stored in table /ISDFPS/CSTACHG (view /ISDFPS/VSTACHG ). This table also contains further information about the check modules.
You define some status change checks in Customizing under .
The following checks are shipped with the standard system:
Object/Assignment |
Check |
Description |
|---|---|---|
Force Element |
/ISDFPS/CL_MM_CHECK_VPA_SE |
|
/ISDFPS/CL_STACHG_EXIST_INFTY |
Existence check for the following infotypes (subtypes):
|
|
/ISDFPS/CL_STACHG_MM_CHECK_I |
||
/ISDFPS/CL_STACHG_MM_CHECK_W |
||
/ISDFPS/CL_STACHG_MM_CHECK_E |
||
/ISDFPS/CL_STACHG_AC_FUND_01 |
||
/ISDFPS/CL_STACHG_AC_HIER_01 |
||
/ISDFPS/CL_STACHG_AC_ROOT_01 |
||
/ISDFPS/CL_STACHG_AC_WBS_02 |
||
/ISDFPS/CL_STACHG_AC_WBS_01 |
||
/ISDFPS/CL_STACHG_AC_CCTR_03 |
||
/ISDFPS/CL_STACHG_AC_CCTR_04 |
||
/ISDFPS/CL_STACHG_AC_PRCTR_09 |
||
/ISDFPS/CL_STACHG_MM_CHECK_WW |
Check whether new storage locations entered for plant change |
|
/ISDFPS/CL_STACHG_AC_ASSET_01 |
||
/ISDFPS/CL_STACHG_EX_* (various classes) |
Check whether the assignments or properties specified exist |
|
/ISDFPS/CL_STACHG_AC_OBJEX_01 |
||
/ISDFPS/CL_STACHG_AC_EX_1950 |
Check whether the data in infotype 1950 is consistent |
|
/ISDFPS/CL_OPERATION_EX_CHK |
Check whether the force elements assigned to the force provider as the initial supplier of personnel and/or material are active |
|
/ISDFPS/CL_STACHG_LOGSYSTEM |
Check whether an operational system is assigned to the force element |
|
/ISDFPS/CL_STACHG_MULTI_ARBPL |
Check whether multiple logistical work centers are assigned to the force element |
|
/ISDFPS/CL_STACHG_SE_1988 |
Check whether a weighting is to be given a status that it already has |
|
Authorized Personnel |
/ISDFPS/CL_STACHG_PS_1988 |
Check whether a weighting is to be given a status that it already has |
/ISDFPS/CL_STACHG_ME_IT1959 |
Check using infotype 1959 whether an installation ID is assigned. |
|
Authorized Material |
/ISDFPS/CL_STACHG_AUTHMAT |
Check existence and data consistency |
/ISDFPS/CL_STACHG_EPA_MPO |
Check that the material master records match in the equipment packages and material planning objects (warning) |
|
Logistical Requirements |
/ISDFPS/CL_STACHG_LOG_REQUIREM |
Check existence and data consistency |
/ISDFPS/CL_MM_CHECK_VPA_SE |
||
Maintenance relationships |
/ISDFPS/CL_PM_CSTA_CHECK_ORDER |
Check open documents when technical objects are relocated |
Infrastructure |
/ISDFPS/CL_STACHG_RE_MAINBE |
|
/ISDFPS/CL_STACHG_RE_INFRA |
The status changes possible here correspond to those of the measure areas ; the objects and assignments concerned correspond to the measure subareas of the organizational measure .
Note