Use of Flow Rates
For infusions (see Creating Orders for Infusions) and nutritional solutions (see Creating Orders for Nutritional Solutions (TPN)) you can define a flow rate, in the compressed order dialog in the Administration Duration
and Unit
fields (with the quick info text Flow Rate/Duration
) and on the Flow Rates
tab page, with the duration and rate or rate which a drug should be administered. You can also use these flow rate definitions in the order templates and for presetting future orders.
By selecting an infusion type, you determine how the drug should be administered. You can choose from the following infusion types:
Intermittent infusions
In the order dialog, the system displays this infusion type as
(Intermittent
). Intermittent infusions are ordered with a specific cycle. In this case you can define a flow rate or an administration duration in the compressed order dialog. In the detail area of the Flow Rates tab page you can also define additional flow rates. All defined flow rates which you created before activating or generating events, are used in the sequence for each infusion administration in the sequence defined by you. The following rate types are available for intermittent infusions: "Start Rate", "Normal Rate", "Bolus", "Minimum/Maximum Rate", "Pause". Following activation or generation "Rate Change", "Pause", "Bolus" and "Minimum/Maximum" are available, which order a one-time rate change at a planned time.
Example
The patient receives a repeat infusion (possibly with one or more flow rates) administered. During the administration of an infusion (an ongoing medication event) you can define a rate change and therefore change the current rate at specific times. You can also pause the infusion or order an additional bolus or continue.
Continual infusions
In the order dialog, the system displays this infusion type as
(Continual
). Continual infusions cannot be assigned without a flow rate. You can define a minimum or maximum rate, to specify the flow rate in the order.
Example
The patient receives a drug administered by an injection pump. At the start of the order an injection is placed in the injection pump and a flow rate set. In case of an ordered rate change, the rate is changed on the injection pump. Once the volume of the injection has been used up a new injection is loaded and placed without a new order. The current rate remains valid. If you define a minimum or maximum you can variably adjust the flow rate of the pump.
Single administration
In the order dialog, the system displays this infusion type as
(Single Administration
). Single administrations enable the administration of the ordered volume but not the further administration of the infusion, once the intended volume has been administered.
Example
Before or during the single administration of such an infusion in an injection pump you can define new "continual rates", "bolus administrations", "minimum/maximum rates" or "pauses", to change the current infusion on the injection pump.
Required Customizing
You must use the system parameter N1MEIFRE
to store a continual cycle with which the system presets the Cycle field in continual infusions or single administrations. See System Parameters for Medication
Use a cycle with the following data in order to guarantee completely correct functionality and display in the order dialog:
Set the Fixed Interval over Several Days indicator
Set From Day to the value 1
Set To Day to the value 0
Set the interval in hours to the value 0
Do not set the Day Cycle indicator
Administration Documentation
In the administration documentation predefined rates are available in the order for single use. You can document deviations using a "Variable Rate" or "Bolus (Variable)", or "Pause (Variable)". With these changes you can differentiate between the flow rates ordered order and those used in the administration or which are documented as deviating, and specify the relevant responsible employee.
The following functions are available in the administration dialog of the eMar
tab page:
Function |
Procedure |
What You Should Know |
|---|---|---|
Select Flow Rate |
Choose |
— |
New Flow Rate |
Choose |
— |
Pause |
Choose |
This function is available if the last rate is not a pause or variable rate with a volume = 0. Otherwise, the |
Bolus |
Choose |
- |
Remove Infusion |
Choose |
In the "Administered Volume (AV)" row the system presets the date and time with the current system date and time and calculates the volume administered until this time. If the available volume is completely administered before the system time, the calculate end date and time are moved forward. |
Undo Removal |
Choose |
— |
New Infusion |
Choose the |
In case of continual infusions the current infusion is removed and a new event is created for the order for each new infusion. If follow-up events exist in a continual infusion, it is no longer possible to undo the removal. |
Note
Note that for infusions with flow rates for the chart the system divides the events with a start and end time based on the flow rates used and planned for each event. In case of flow rates with the flow rate 0 ("Pause") no events are transmitted to the chart during this pause
flow rate.
You can use
(Quick Administration
) as follows:
Continual infusions
The system saves all flow rates with a planned start in the past, as used, calculates the end date/end time based on the rate change used and the ordered planned quantity and saves these.
Intermittent infusions and single administrations
The system saves all flow rates which have a duration, as used. If the volume has already been consumed, the system creates newly hung infusions (hangs) according to the existing preparations. Note that the planned time of a rate change can also be a time in the future.
The report Medication – End Medication Events
(RN1ME_END_EVENTS
) automatically sets events which were already documented in the system as administered, to Ended
status. This includes events which are documented as removed and events with a calculated end date/time which is at least 12 hours in the past. These events cannot then be changed.
In Medication Orders
and Medication Events
view types additional columns are available for the infusion type, the current rate type, the current rate, the next due rate, the next due rate change and the corresponding units.
Note
Note that migration is not available for old orders. Orders with a rate type which does not correspond to the necessary definition, must be renewed.
To suspend one or more valid active orders, choose
(Suspend Order
). The system automatically sets a pause rate at the time of the suspension. See Suspending an Order.
To resume one or more valid inactive orders, choose
(Resume Order
). You must manually create the rates necessary for resumption. See Resuming an Order.
You can adapt the dosage information of an order using the Change Dose
function. The system will open the infusion order concerned in the detail dialog and create a new flow rate which must be manually adapted. See Changing Doses