Parameter: JCO_CPIC_TRACE_LEVEL

Definition

Turns on the Java Connector (JCo) CPIC traces. Possible levels are 0 (trace is off) to 3 (most verbose trace).

Description and Use

Turns on the Java Connector (JCo) CPIC traces. Possible levels are 0 to 3. Set it up to 0 to disable JCo CPIC traces.

Syntax and Constraints

Defined Constraints

The SAP CC Core Server system verifies the following constraints:

Instance Type Constraint
Dispatcher instances The parameter must be less than or equal to 3 .
The parameter must be greater than or equal to 0 .
Bulkloader instances The parameter must be less than or equal to 3 .
The parameter must be greater than or equal to 0 .

Technical Details

For more information, consult this section.

Name JCO_CPIC_TRACE_LEVEL

Turns on the Java Connector (JCo) CPIC traces. Possible levels are 0 (trace is off) to 3 (most verbose trace).

Category Parameter
Type Integer
Access (RO/RW)

RW(+): Dynamic Read / Static and Dynamic Write

An immediate change is possible but is temporary. When it is relevant, change the permanent settings used by the SAP CC Core Server system when it restarts.

Use the Admin+ user interface to change the runtime values or the permanent values of this system parameter in an instance of the SAP CC Core Server system or in multiple instances.

Groups
Instance Types This system parameter is available in the following types of instances in a running SAP CC Core Server system:
  • dispatcher, bulkloader
Default Values (Factory Settings)

The predefined default values are:

Instance Type Value
Dispatcher 0
Bulkloader 0

You can use a default value to reset the runtime value or the restart value (persistent) in the Admin+ user interface.

Note

A default value is part of the factory settings of the SAP CC Core Server systems. It differs from the original value set during the installation or after the Customizing activities.

In Admin+, you can reset a parameter value to this default value, but it is not recommended:

  • This value may differ from the original value set during the installation of your SAP CC system.
  • Note that it may also differ from the value defined by the implementation project team and set during the Implementation Phase of the integration project.
Verify the values in your running SAP CC systems before to use the reset command.

Constraints

The SAP CC system checks the following constraints:

Dispatcher instances The parameter must be less than or equal to 3 .
The parameter must be greater than or equal to 0 .
Bulkloader instances The parameter must be less than or equal to 3 .
The parameter must be greater than or equal to 0 .