In the context of the Consistency Check of the CCMS Monitoring Infrastructure, you can have problems automatically corrected. If you have created a check group (more information: Checking and Distributing Settings for Selected MTEs and Monitors), you can also distribute the reference threshold values and method assignments of the nodes in the check group to all monitored systems. You have two options for doing this:
You can have the selected check object repaired after the consistency check is performed in transaction RZ50, by choosing (more information: Displaying the Results of the CCMS Consistency Check).
You can create a check area, in which you have troubleshooting automatically started for selected check objects, as soon as the consistency check is performed (more information: Restricting the CCMS Consistency Check to Specific Topics).
Automatic troubleshooting is available for the following check objects:
Check Object |
Troubleshooting |
---|---|
|
The segment table is reorganized, that is, inaccessible monitoring segments, for example, for inactive application servers, are removed from the segment table. |
|
The nodes that have a method status with an error are reset (more information: Resetting MTEs and Alerts). This means that values are provided for the relevant nodes again, since the data collection methods are restarted. |
|
|
|
The central system dispatching job is scheduled (more information: Activating and Deactivating Method Execution). |
|
The jobs required to collect CPH data are scheduled (more information: Collecting and Reorganizing Performance Values). |
|
The jobs for managing monitoring pauses are scheduled (more information: Managing Monitoring Pauses in the Alert Monitor). |
|
The background dispatching job is scheduled (more information: Activating and Deactivating Method Execution). |
|
The agent performs a reinitialization of the shared memory area of the agent (command -initshm). |
|
The threshold values for the corresponding nodes are set as specified in the check group (more information: Checking and Distributing Settings for Selected MTEs and Monitors |
|
The assigned analysis and auto-reaction methods for the corresponding nodes are set as specified in the check group (more information: Checking and Distributing Settings for Selected MTEs and Monitors |
|
The assigned central auto-reaction methods for the corresponding nodes are set as specified in the check group (more information: Checking and Distributing Settings for Selected MTEs and Monitors |