Generating Symbols from Value Assignment Types
Prerequisites
See
WWI: Using the WizardProcedure
The Symbol Tree dialog box appears.
There are several ways of influencing the result of the search in the symbol tree (see
WWI: Using the Wizard).The Wizard Group Options dialog box appears.
The value assignment type selected is entered in the Substance Characteristic Category field.
The Filter field is ready for input. The text for the value assignment type has been entered as a search criterion, Relative density, for example.
You can modify the text in the Filter field. Generic entries are accepted and the search is case sensitive.
If you do not set the indicator, the data is displayed in list format with three-column tables.
If you want to display phrases for characteristic values, Word checks if the corresponding phrases are available. If not, the system displays the Phrase Search dialog box in which you can modify the search criteria according to the procedure
Result

List Output
____________________________________________________________________
Report Template Layout:
<11BRG010(M,SAP_EHS_1013_006)>
<13BNG017(+:01G1013006VA)>
|
<03EHS_L_TEXT(EHSXP-E08.00290020)> |
: |
<01G1013006VA> |
<13ENG017>
<13BNG018(+:01G1013006ET)>
|
<03EHS_L_TEXT(EHSXP-E11.00900130)> |
: |
<01G1013006ET> <01G1013006E1(P)> |
<13ENG018>
<11ERG010>
____________________________________________________________________
Layout of Generated Report:
Relative density: 0.9 g/cm3
Temperature: 20°C <

To ensure that the temperature "20°C <" is displayed correctly as "<20°C", you must reverse the sequence of symbols on the report template (after you have inserted the symbols using the Wizard). However, in the Wizard, the sequence may not be changed. If you change the sequence, a new line (or table column, see below) is created for each phrase so that the temperature is separated from its accuracy.
Instead, you can set the phrase indicator for the symbol with the incorrect syntax, and change the phrase after you have exited the Wizard.
Table Output
____________________________________________________________________
Report Template Layout:
|
<03EHS_L_TEXT(EHSXP-E08.00290020)> |
<03EHS_L_TEXT(EHSXP-E11.00900130)> |
<11BRG012(M,SAP_EHS_1013_006)>
|
<01G1013006VA> |
<01G1013006ET> <01G1013006E1(P)> |
<11ERG012>
____________________________________________________________________
Layout of Generated Report:
|
Density |
Temperature |
|
0.9 g/cm3 |
20°C < |