Entering content frameFunction documentation Manufacturing Events Locate the document in its SAP Library structure

Use

Manufacturing event is a generic term for events that are provided by different applications. The Manufacturing Data Access interface can be used to exchange events. Every application that is registered at the interface as a service can provide events and subscribe to them.

For more information, see Manufacturing Data Access.

For more information on how to define the data access in PI sheets and manufacturing cockpits, see Type 0: Definition of Manufacturing Data Access.

Prerequisites

OPC Events

To use events of the services ODA (OPC Data Access) and OAE (OPC Alarms/Events), you must first have created a subscription in Customizing.
To do so, go to Customizing for Process Management and choose SAP ODA (OPC Data Access).

For more information about SAP ODA, see Structure linkSAP OPC Data Access.

Features

The following services provide events:

The following services can access events:

Addresses are used to access events. They start with the name of the service. The remaining address parts depend on the service. You can use value help to select events.

Service MDA

This service offers the generic services BROADCAST and REDIRECT.

Using BROADCAST, you can define user-specific events. A generic data point is available for this to which you can write any value. The value change of this data point is published as an event. Other services can subscribe to this event.

The address for the propagation of the event is made up as follows:

Event

Address

Event to be propagated individually

MDA:BROADCAST.SEND.<Category>
<Category>
can be replaced by any character string. Note that the entry is case-sensitive.
Example
MDA:BROADCAST.SEND
.DPV
Service MDA, the user-defined event
DPV is to be published.

The address for the subscription to the event is made up as follows:

Event

Address

An event that was propagated individually

MDA:BROADCAST.<Category>
<Category>
can be replaced by the character string that you have used for event propagation. Note that the entry is case-sensitive.
Example
MDA:BROADCAST.SEND
.DPV
Service MDA, the user-defined event
DPV is to be subscribed.

Parameters of MDA Events

The following parameters can be transferred as data points together with the event. The address is made up as follows:

Parameter

Address

The system logon from which the event was sent

MDA:BROADCAST.PARAM.SESSION

The terminal from which the event was published

MDA:BROADCAST.PARAM.TERMINAL

The time stamp for which the event was published

MDA:BROADCAST.PARAM.TIMESTAMP

The user who published the event

MDA:BROADCAST.PARAM.USER

The value of the data point that is transferred with the event

MDA:BROADCAST.PARAM.VALUE

ExampleExample for BROADCAST

The fill level of tank #333 is to be recorded in a manufacturing cockpit. The up-to-date fill level is to be published as an event by pressing a button. In the address MDA:BROADCAST.SEND.<Category>, <Category> was replaced by DPV meaning data point value.

In the cockpit definition, you define the following characteristics in the sequence specified:

 

Characteristic

Characteristic Value

 

PPPI_DATA_REQUEST_TYPE

Simple data request

 

PPPI_DATA_POINT_NAME

Tank #333

 

PPPI_OUTPUT_CHARACTERISTIC

PPPI_DATA_POINT_NAME

 

PPPI_INPUT_REQUEST

Record fill level

 

PPPI_DATA_POINT_VALUE

0

 

PPPI_VARIABLE

VAR_DPV

 

PPPI_REQUESTED_VALUE

PPPI_DATA_POINT_VALUE

 

PPPI_DATA_ACCESS

Manufacturing Data Access

 

PPPI_BUTTON_TEXT

Publish

 

PPPI_FUNCTION_DURING_DISPLAY

Permitted

 

PPPI_EXPORT_DATA

MDA:BROADCAST.SEND.DPV

 

PPPI_STRING_VARIABLE

VAR_DPV

In transaction CO69 – Create Process Messages Automatically, a process message is to be created automatically whenever the event propagated in the example above is sent. You define the following in transaction CO69:

Service PSH

The service PSH offers the following events. The event address is made up as follows:

Event

Address

PI sheet was completed

PSH:<No. of PI sheet>.COMPLTD
Example
PSH:100000000000004711.COMPLTD

Service PSH, PI sheet
100000000000004711 was completed

PI sheet was created

PSH:<No. of PI sheet>.CREATED
Example
PSH:100000000000004711.CREATED

Service PSH, PI sheet
100000000000004711 was created

Maintenance was started

PSH:<No. of PI sheet>.LOGIN
Example
PSH:100000000000004711.LOGIN

Service PSH, user logged on to maintain PI sheet
100000000000004711.

Maintenance was exited

PSH:<No. of PI sheet>.LOGOFF
Example
PSH:100000000000004711.LOGOFF

Service PSH, user logged off from PI sheet
100000000000004711.

Data was reported

PSH:<No. of PI sheet>.REPORTD
Example
PSH:100000000000004711.REPORTD

Service PSH, data of PI sheet
100000000000004711 was reported.

Data was saved

PSH:<No. of PI sheet>.SAVED
Example
PSH:100000000000004711.SAVED

Service PSH, PI sheet
100000000000004711 was saved.

Global variables were changed

PSH:<No. of PI sheet>.VARCHGD
Example
PSH:100000000000004711.VARCHGD

Service PSH, global variables in PI sheet
100000000000004711 have changed.

Service PMC

The service PMC offers the following events. The event address is made up as follows:

Event

Address

Manufacturing cockpit was started

PMC:<Plant>.<Cockpit name>.LOGIN
Example
PMC:0001.MYCOCKPIT.LOGIN

Service PMC, user logged on to maintain cockpit
MYCOCKPIT.

Manufacturing cockpit was exited

PMC:<Plant>.<Cockpit name>.LOGOFF
Example
PMC:0001.MYCOCKPIT.LOGOFF

Service PMC, user logged off from cockpit
MYCOCKPIT.

Global variables were changed

PMC:<Plant>.<Cockpit name>.VARCHGD
Example
PMC:0001.MYCOCKPIT.VARCHGD

Service PMC, global variables in cockpit
MYCOCKPIT have changed.

Service ODA

The service ODA offers the following events. The event address is made up as follows:

Event

Address

Value change of an OPC Data Access subscription occurred

ODA:<Plant>.<OPC item>.VCHD
Example
ODA:0001.MYITEM.VCHD

Service ODA, OPC item
MYITEM, value has changed.

Service OAE

The service OAE offers the following events. The event address is made up as follows:

Event

Address

Event of an OPC Alarms/Events subscription occurred

OAE:<Plant>.<OPC subscription>
Example
OAE:0001.MYSUBSCRIPTION

Service OAE, OPC subscription
MYSUBSCRIPTION was triggered.

Parameters of OPC Events

The following parameters can be transferred as data points together with the event. The address is made up as follows:

Parameter

Address

Acknowledgement cookie

OAE:<Plant>.<OPC subscription>.ACKC
Example
OAE:0001.MYSUBSCRIPTION.ACKC

Event was acknowledged

OAE:<Plant>.<OPC subscription>.ACKD
Example
OAE:0001.MYSUBSCRIPTION.ACKD

Acknowledgement required

OAE:<Plant>.<OPC subscription>.ACKR
Example
OAE:0001.MYSUBSCRIPTION.ACKR

Status "active" of event condition

OAE:<Plant>.<OPC subscription>.ACTV
Example
OAE:0001.MYSUBSCRIPTION..ACTV

Event condition

OAE:<Plant>.<OPC subscription>.CND
Example
OAE:0001.MYSUBSCRIPTION.CND

Event date

OAE:<Plant>.<OPC subscription>.DATE
Example
OAE:0001.MYSUBSCRIPTION.DATE

Event message text

OAE:<Plant>.<OPC subscription>.MSG
Example
OAE:0001.MYSUBSCRIPTION.MSG

Severity

OAE:<Plant>.<OPC subscription>.PRIO
Example
OAE:0001.MYSUBSCRIPTION.PRIO

OPC limitation

OAE:<Plant>.<OPC subscription>.QL
Example
OAE:0001.MYSUBSCRIPTION.QL

OPC subquality

OAE:<Plant>.<OPC subscription>.QS
Example
OAE:0001.MYSUBSCRIPTION.QS

OPC quality

OAE:<Plant>.<OPC subscription>.QUAL
Example
OAE:0001.MYSUBSCRIPTION.QUAL

Event text

OAE:<Plant>.<OPC subscription>.RT
Example
OAE:0001.MYSUBSCRIPTION.RT

Event subcondition

OAE:<Plant>.<OPC subscription>.SCND
Example
OAE:0001.MYSUBSCRIPTION.SCND

Event source

OAE:<Plant>.<OPC subscription>.SRC
Example
OAE:0001.MYSUBSCRIPTION.SRC

Event time

OAE:<Plant>.<OPC subscription>.TIME
Example
OAE:0001.MYSUBSCRIPTION.TIME

 

 

 

 

 