Monitoring of the Maximum Permitted Storage Period This function helps you to monitor from
disposal processing
whether the maximum storage periods for
wastes
are being kept to.
The entry document contains the following data:
Waste quantity
Maximum storage period permitted
Note
If you enter a waste and a
plant
in the
Disp. proc. plt
field when you create or change an entry document, the system proposes the value specified for the plant in the
Max. storage
field in the waste
material master
as the maximum permitted storage period. You can change this value in the detail view of the entry document.
Caution
The default value for the maximum permitted storage period is not updated. This means that if you enter a different storage period in the
material master
or if you enter another plant for which a different storage period has been entered in the material master, this different storage period is
not
automatically reread and adopted.
The system displays whether the maximum storage period is being kept to for each entry document in the
Max. stor.
field in the document overview in
disposal processing
, by means of traffic light icons as follows:
Green light (
): Maximum storage period is not exceeded.
Amber light (
): Maximum storage period is not exceeded, but current date is within the alert period.
Red light (
): Maximum storage period is exceeded.
The icon that is displayed for an entry document is determined again using the current date each time you access
disposal processing
. Depending on whether this date is before or after the end of the maximum storage period, the system displays the icons as follows:

The start of the maximum storage period is determined as follows:
If you enter a waste quantity and a maximum storage period and save the entry document, the system adopts the date from the
Document date
field as the start of the maximum storage period.
If you execute the
post change
or
storage bin transfer
function and set the
Upd. stor. strt
indicator, the system adopts the current system date as the start of the maximum storage period. The date in the
Document date
field is not changed.
The end of the maximum storage period is calculated from the start of the maximum storage period and the maximum permitted storage period from the entry document. You can specify the alert period in the
Alert period
field in the
entry tool
.