Uploading ELS with a Work Step Sequence

You can use this function to upload engineered labor standards (ELS) from another external system.

Use

There are two ways to copy existing data:

  • By uploading a local file, such as a CSV file.

  • By uploading a file from an application server.

    In this case, Extended Warehouse Management (EWM) uses a connection to the Legacy System Migration Workbench (LSMW).

You can upload existing data for the following objects in Labor Management:

  • Formula or condition

  • Work step

  • Labor standard of the work step

  • Work step sequence

  • Assignment of work step sequence

Prerequisites

The CSV file has a header line and the following column format:

Formula or condition

LGNUM

PROCS

FORMULA

FORMULA_TYPE

VALID

Char 4

Char 4

Char 4

Char 1

Char 1

Formula or condition

WGT_UOM

VOL_UOM

DIST_UOM

TIME_UOM

FORMULA_TXT

FORMULA_ELEMENT

Char 3

Char 3

Char 3

Char 3

Char 40

Char 100

Work step

LGNUM

STEP

DESCRIPTION

Char 4

Char 4

Char 40

Labor standard of the work step

LGNUM

STEP

NUM

CONDI

TION

CONSTANT

UNIT

FORMULA

ACTIVE

Char 4

Char 4

Char 5

Char 4

Char 16

Char 3

Char 4

Char 1

Work step sequence

LGNUM

SEQUENCE

NUM

STEP

SEQUENCE (included)

ACTIVE

Char 4

Char 4

Char 5

Char 4

Char 4

Char 1

Assignment of work step sequence

LGNUM

PROCS

ACTIVITY AREA

OBJECT TYPE

NUM

SEQUENCE

ACTIVE

Char 4

Char 4

Char 4

Char 1

Char 5

Char 4

Char 1

The LSMW uses the following structures:

  • /SCWM/S_ELS_LSMW_FRML - Formula or condition

  • /SCWM/S_ELS_LSMW_ST - Work step

  • /SCWM/S_ELS_LSMW_STE - Labor standards of the work step

  • /SCWM/S_ELS_LSMW_SEQ _- Work step sequence

  • /SCWM/S_ELS_LSMW_ASS - Assignment of work step sequence

Activities

You call the function from the SAP Easy Access screen, by choosing Start of the navigation pathExtended Warehouse Management Next navigation step Settings Next navigation step Labor Management Next navigation step Upload Engineered Labor StandardsEnd of the navigation path.

  1. Specify the type of host from which you want to upload the file:

    • From a local computer

    • From an application server

  2. Use the Delete Existing Data field to select whether the uploaded data is allowed to overwrite existing settings.

  3. Enter the file name and choose Upload.

    The system uploads the data and displays it on the Loaded Data tab page. If you are working with a file on an application server, the system fetches the data from the application server, and displays it to you.

  4. Make corrections if required.

    If you upload a file from an application server, you can make corrections directly in the LSMW and then upload the file again.

  5. Choose Execute with the quick info Start Data Transfer .

    The system stores the data in the database. On the Successful Changes tab page, you can find all the data that has been successfully created. On the Failed Changes tab page, you can find all the data that EWM was unable to create. The Message column on this tab page also shows you the additional message text.