MFS Resource Pick-Up Points
Use
You can create warehouse tasks to put away handling units (HUs) from resource pick-up points in a material flow system (MFS) into automated high bay storage. The system creates the warehouse tasks based on the following:
-
Current communication point
-
HU data
-
Stock data
-
Equipment status
For more information, see Putaway Strategy.
Prerequisites
-
You have made the Customizing settings for MFS (see Setting Up MFS for Case Conveyor Systems).
In particular, you have ensured that action function module /SCWM/MFSACT_CASE_RSRC_PP for MFS resource pick-up points is called for your telegram type at the correct point.
-
You have maintained accessible aisles per communication point (see Aisles and Levels Accessible by Communication Point).
-
You have maintained accessible aisles per resource (see Aisles and Levels Accessible by Resource).
Features
-
If the HU is located in a different place to where it should be, based on the evaluation of the case conveyor routing definition for the logical destination of the telegram, then it is posted to the new location.
-
The corresponding resource, communication point, and communication channel are checked for exceptions. If there is an exception, for example, the resource is blocked by maintenance, then the incoming telegram can be set to a retry state (see Reprocessing of Incoming Telegrams).
-
Open warehouse tasks for the HU are checked as follows:
-
If there is an open HU warehouse task accessible by the current communication point or resource, the system uses this warehouse task.
-
If there is an open HU warehouse task for a different aisle or a product warehouse task, the system creates a HU warehouse task for the error bin of the resource.
-
If no warehouse task exists, the system creates a new warehouse task based on the current communication point, HU data, stock data, and equipment status.
-
You can use BAdI: Determination of Handling Units Used in Telegrams to inform standard coding about HUs that should be processed based on the telegram. In the standard setup the default implementation for this BAdI is class /SCWM/CL_EI_MFS_HU_DET_TELE. The default implementation returns one HU that is part of the standard telegram structure. For more information, see Customizing for Extended Warehouse Management under .