Internal Exceptions

The system sets an internal exception if an error occurs (if a scanner has reported an unknown handling unit (HU), for example). The system sets the following exceptions internally. You must supplement these internal exceptions by external ones in Customizing. The external exception then specifies:

  • The wording of the error message that appears in the alert monitor

  • How the system reacts (for example, diversion of HU to clarification bin)

  • Whether a further follow-on action takes place (for instance, notification of a remote control station via mail or text message)

The application log should contain error messages that clarify the reason why the internal exception was set.

Internal Exception

Error Situation

Context/Step

Use

MFS1

The PLC confirms a warehouse task: The destination does not correspond to the expected position. (There is no open warehouse task for the relevant communication point.)

MF3/A0

The system reposts the HU to the point reported by the PLC. If you want to log this variance, assign an external exception (such as MLOC) to the internal exception MFS1 and activate the follow-on action alert for it. If you want such "strays" to be diverted to the clarification bin, assign the internal process code CRCL to the external exception.

MFS2

Release conveyor segment: The PLC reports a conveyor segment or conveyor segment group as ready again.

This exception facilitates the option of logging the event and triggering possible follow-on actions.

MF2/A0

If you want this event to be logged in the alert monitor, assign an external exception to this internal exception, define the text Conveyor segment ready for the former, and activate the follow-on action alert.

MFS3

Not applicable

Not applicable

Not applicable

MFS4

Release resource: The PLC reports that a resource is ready again.

This exception facilitates the option of logging the event and triggering possible follow-on actions.

MF4/A0

If you want this event to be logged in the alert monitor, assign an external exception to the internal exception, define the text Resource ready for the former, and activate the follow-on action alert.

MFS5

Release communication point: The PLC reports that a communication point is ready again.

This exception facilitates the option of logging the event and triggering possible follow-on actions.

MF5/A0

If you want this event to be logged in the alert monitor, assign an external exception to the internal exception, define the text Communication point ready for the former, and activate the follow-on action alert.

MFS6

Release communication channel: This exception facilitates the option of logging the event and triggering possible follow-on actions.

MF1/A0

If you want this event to be logged in the alert monitor, assign an external exception to the internal exception, define the text Communication channel ready for the former, and activate the follow-on action alert.

MFS7

Unknown HU reported: The PLC has reported an HU that is unknown to the SAP Extended Warehouse Management (SAP EWM) system.

MF3/A0

If you want to have the unknown HU automatically diverted, define the external exception Unknown HU reported. Assign the internal process code HUNO to this exception. The system then creates a new empty HU and diverts it to the clarification bin.

MFS8

Putaway Not Possible: SAP EWM determines at an aisle decision point that a rough destination bin could not be determined for the HU (no empty bin or suitable partially occupied bin was found).

MF6/A0

If you want to have the HU automatically diverted, define the external exception Putaway Not Possible. Assign the internal process code CRCL to this exception. The system then sets a defect on the HU and diverts it to the clarification bin.

MFS9

HU Content is Subject to Order Reduction: SAP EWM determines that the content of the handling unit (HU) moved is subject to order reduction (see Order Reduction).

MF3/A0

MF6/A0

If you want to have the HU automatically diverted, define the external exception HU Content is Subject to Order Reduction. Assign the internal process code CRCL to this external exception. The system then assigns a defect to the HU and diverts it to the clarification bin.

The BC Set /SCWM/MFS_EXCEPTION_ORD_RED is available as an example configuration.