Maintaining Table TMCA for CMC ROC Calculation

Use

The maximum turnaround time (max. TAT) determines the maximum duration that an unserviceable rotable may remain in a work center. The CMC uses the max. TAT, if defined, in the ROC-based scheduling of orders/operations. To determine consumption quantities correctly for the ROC calculation you must enter ROTC in field STGRP1 in table TMCA for all movement types that you use for rotable components. This updates information structure S464 in the Inventory Controlling area of the Logistics Information System.

Procedure

  1. Choose Start of the navigation path System Next navigation step Services Next navigation step Table Maintenance Next navigation step Extended Table Maintenance End of the navigation path

  2. The Maintain Table Views: Initial Screen screen appears.

  3. Enter TMCA in the field Table/view .

  4. Select the button Maintain .

  5. The Change View "Evaluating movement types for LIS update": Overview screen appears.

  6. In column STGRP1 enter ROTC for every movement type that you want to update in information structure S464.

  7. Save your entries.