If desired, you can configure certain display settings for the Group or Notifications
tiles.
Procedure
-
On the front-end server, run transaction
SE80.
The Object Navigator screen appears.
-
From the dropdown list, select BSP Application.
-
Enter ARSRVC_SM and choose
Display.
-
Go to .
-
Set up the Notifications tile:
-
Choose
notification.tile.chip.xml.
The XML file displays.
-
If desired, change the default values below to suit your business needs:
Note Change only the values in the table below.
Parameter Name |
Description |
Default Value |
number_of_notifications |
Maximum number of unread notifications the
system retrieves |
10 |
display_time |
Time in seconds that a notification is displayed |
10 |
transition_time |
Time in seconds that the system takes to scroll to the next notification |
1 |
refresh_interval |
Time in seconds that the system waits before
retrieving new notifications from the back-end
system |
300 |
-
Save your changes.
-
If desired, set up the Group tile:
-
Choose
group.tile.chip.xml.
The XML file displays.
-
If desired, change the default values below to suit your business needs:
Note Change only the value in the table below.
Parameter Name |
Description |
Default Value |
refresh_interval |
Time in seconds that the system waits before
retrieving new information from the back-end
system |
300 |
-
Save your changes.