Show TOC

Function documentationAdditional Functions in InfoPackage Maintenance Locate this document in the navigation structure

 

Features

For All InfoPackages
Defining Control Parameters for Data Transfer

Under   Scheduler   DataSource Default Data Transfer   you can override the settings you made in BW Customizing for a particular DataSource and a particular update mode.

More information: Maintaining Data Transfer Control Parameters for DataSources

Defining the Maximum Wait Time Before a Request is Determined to have an Error

Under   Scheduler   Timeout Time   you define the maximum wait time before the system determines a request for this InfoPackage to have an error. If the system has not received any (additional) data record before the maximum wait time has elapsed, the request is assigned the error status.

You can use this function to override the system-wide setting for a particular InfoPackage. The default setting for each InfoPackage is the same as the system-wide setting you made under   Monitor   Settings  , or in BW Customizing.

Defining the Request Status for Warnings

Under   Scheduler   Treatment of Warnings   you define how the system reacts to any warnings that appear; that is, whether a request for this InfoPackage is given the green, yellow, or red status in such a case. You can use this function to override the system-wide setting for a particular InfoPackage. The default setting for each InfoPackage is the same as the system-wide setting you made under   Monitor   Settings  , or in BW Customizing.

Recommendation Recommendation

We recommend you not to assign the status yellow to the request when a warning arises, since this prevents subsequent processing steps from starting, and the request would then be denoted as having an error after the time-out time had elapsed anyway.

End of the recommendation.
Defining the Request Status if there is no Data in the Source System

Under   Scheduler   Color of Traffic Light for Empty Request   you define how the system reacts if there is no data in the source system for the data request.

Restricting the Number of Selection Values

Under   Extras   Restrict Number of Selection Values   you can set a indicator for the InfoPackage stipulating that a maximum of 1000 single and interval selection can be defined. In the default setting, this indicator is set.

Performing an Automatic Metadata Comparison for a Data Request from SAP Source Systems

Under   Extras   Synchronize Metadata   you can define that a metadata comparison of the DataSource in BW with the source system takes place, and that the DataSource is replicated if necessary.

For reasons of compatibility the indicator for DataSources 3.x is not set in the default setting. For DataSources in the dataflow with transformation, the indicator is set.

More information: Replication of DataSources in the section Replication for Data Request.

For InfoPackages 3.x
Test Delete Selection at Start

If you want to automatically delete or cancel requests for the InfoCube after loading you can go to   Scheduler   Test Delete Selections at Start   and specify whether the requests are to be deleted or canceled with or without the system displaying a warning.

Defining Parallel Execution of Processes

Under   Extras   PSA -> DTA Parallel   you can set the maximum number of parallel processes for the update process from DataSource 3.x of this InfoPackage to the defined data targets.

More information: BW Background Management, Logs and Tools

For InfoPackages with Delta Process
Displaying Initialization for a DataSource

For InfoPackages that can load deltas, you can display all initializations for the DataSource under   Scheduler   Initialization Options for Source System  .

More information: Tab page: Updating in the section Initialization of Delta Process.

Denoting a Request as a Repair Full Request

You can use a request that was denoted as a repair request using   Scheduler   Repair Full Request   to perform a full update in any InfoProvider, even if this InfoProvider already contains data from an initialization run or deltas for this DataSource / source system combination, and has overlapping selection conditions.

More information: Tab page: Updating in the section Full Update.

For InfoPackages for File Source Systems
Defining Parallel Execution of Processes

Under   Extras   Load New DataSource in Parallel   you can set the maximum number of parallel processes for the transfer process from a file source system to a DataSource of object type RSDS.

More information: Setting Parallel Processing of BW Processes