For normal operation, you must maintain the operation mode timetable.
Choose .
Choose .
The system displays the timetable for the 24 hour cycle.
To assign other times to the operation mode, choose Normal operation (24 hr) and Change.
Double-click on the start time and end time that you require.
Choose Assign to assign these times to the operation mode.
Enter the name of the operation mode to be active for the time period that you defined.
You can only select productive operation modes.
Save your changes.
Finally, save the table.
You must always define a full 24 hour cycle, that is, the operation modes must be set up for 24 hour system operation. If the timetable is not defined:
The start configuration according to the profile will remain active
No unattended automatic operation mode switch is possible
The job scheduling monitor will not function properly
When a job is created or released with start date/time, it will not be possible to check whether background processes are available at the start time
Jobs that are scheduled to start when the operation mode is switched are not started.