Proceed as follows:
In the quality cockpit, choose Create New
.
The system opens an embedded view to enter selection values for your new project.
New Project
screen area.
Provide the following details about your projects:
Project Name
Description
Project Owner
Custom Classification Variants
Predefined as default.
You can overwrite the ATC (ABAP Test Cockpit) classification by defining that a specific check is an error instead of a warning or information. To do so, choose the Edit
button and enter the ATC Error Class
and ATC Error Code
that you want to change and enter the Custom Classification
. You can also import and export the Custom Classification
variant.
Custom Time Estimation Variant
Predefined as default
You can overwrite the default time estimation that is needed to resolve an error of one of the checks. To do so, choose Edit
and enter the estimated time in the Default Time Estimation (for unassigned errors)
field. The default time is 0.2 hours which you can change by entering a different value in hours.
Target Thresholds for Critical Errors
Example
Enter 100,00 if you aim to solve 100% of the errors.
Target Thresholds for Default Errors to be Improved
Check the Object Quality Levels
Select the Error
, Warning
and/or Information
checkboxes.
System Selection
screen area
Enter a Quality System ID
.
Choose Select the ATC variant for the quality system
and make the necessary entries.
Object Selection
screen area
Select at the Package
containing Select
the objects that you want to use for your quality project.
Filter for the objects: Object Type
, Application
, Project Owner
.
Analysis Schedule
screen area
Define a Start Date
, Start Time
, and Frequency
to determine when the ATC results are retrieved for the analysis of your quality project.
Choose Save Project
to confirm your entries.