Monitoring Component Health CheckLocate this document in the navigation structure

Prerequisites

You must have the required Process Integration Monitoring roles assigned to monitor the PI components. For more information, see Monitoring Roles .

Context

You use this procedure to analyze the health check of the individual PI components and check whether all the individual health check metrics for a PI component are successful. You use the self-test to monitor the health check of a PI component.

Using the status indicators you can analyze the self-test results. The status indicator of the test result can be green, red, yellow, or gray. The overall self-test result for a PI component depends on the individual metric result and the least status indicator for the metric result represents the overall self-test result. The overall self-test status will only have a green indicator ( Green Square) if all the individual health check metrics are green.

Note

For non-central adapter engine the PI components that you can monitor are adapter engine and mapping runtime.

The table below shows the various status indicators and there meaning:

Status Indicator

Meaning

Green Square

Component is available and is functioning correctly.

Red Circle

Component is not available.

Yellow Triangle

Component is available but it is not functioning correctly.

Grey Rhombus

No information from the component is available.

Procedure

  1. Choose one of the options mentioned below to launch Component Monitor:
    • If you want to monitor using SAP NetWeaver Administrator, go to http://[hostname]:[port]/nwa and navigate to Start of the navigation path SOA Next navigation step Monitoring Next navigation step PI Component Monitor End of the navigation path

    • If you want to monitor using Process Integration tools, go to http://[hostname]:[port]/pimon and navigate to Start of the navigation path Monitoring Next navigation step Adapter Engine Next navigation step Component Monitor End of the navigation path

  2. In the Available Components table, select the Component Type and Component Name and then choose GO .
  3. Select the component that you want to monitor and choose Repeat Self-Test .

    In the Available Component table, in the Self-Test column, Self-test test results are displayed.

Results

For any PI component, if the status indicator is Green Square, it indicates that all the health check metrics are successful. If the status indicator is either Red Circle or Yellow Triangle or Grey Rhombus, it indicates that one of the health check metric or all the health check metrics has failed.

Note

In the Self-Test table, in the Status column, test result of each health check metric is displayed.