Function documentationZone B Limit Alarm

 

Alarm rule 6 is triggered when multiple points (in a series) are in or beyond Zone B (upper or lower Zone B).

For alarm rule 6, the limit and length values are used for both the upper and lower charts. The data points on the chart are checked for the specified number of points in or beyond Zone B. For alarm rule 6, an alarm is triggered when there are <Limit> number of data points in the <Length> that are either in or beyond Zone B. You can also use other alarms, 36, 37, 38, or 39.

Features

General guidelines to detect instability in Zone B for different chart types are as follows:

Chart Types

Maximum Points to apply Rule

X-bar

4 of 5 successive points in or above upper or lower Zone B

Individual Chart

Median

R-chart when the minimum subgroup size is 4

R-chart when the minimum subgroup size is less than 4

3 successive points in or above upper Zone B

Following are the alarm properties defined for Zone B limit Alarm:

Alarm Name

Property Name

Parameter

Data Type

Description

Allow Upper Chart Zone B Limit Alarm

UpperWEZoneBAlarmEnabled

Boolean

Enables Zone B alarm points for upper charts

Allow Lower Chart Zone B Limit Alarm

LowerWEZoneBAlarmEnabled

Boolean

Enables Zone B alarm points for lower charts

Alarm 6

Limit of Zone B Limit Alarm

WEZoneBAlarmLimit

Integer

Sets the limit and length values to check data points within Zone B

Length of Zone B Limit Alarm

WEZoneBAlarmLength

Integer

Alarm 36

Limit of Upper Chart Upper Zone B Limit Alarm

WEUpperChartUpperZoneBAlarmLimit

Integer

Defines the limit and length values to check points in upper Zone B of the upper chart

Length of Upper Chart Upper Zone B Limit Alarm

WEUpperChartUpperZoneBAlarmLength

Integer

Alarm 37

Limit of Upper Chart Lower Zone B Limit Alarm

WEUpperChartLowerZoneBAlarmLimit

Integer

Defines the limit and length values to check points in lower Zone B of the upper chart

Length of Upper Chart Lower Zone B Limit Alarm

WEUpperChartLowerZoneBAlarmLength

Integer

Alarm 38

Limit of Lower Chart Upper Zone B Limit Alarm

WELowerChartUpperZoneBAlarmLimit

Integer

Defines the limit and length values to check points in upper Zone B of the lower chart

Length of Lower Chart Upper Zone B Limit Alarm

WELowerChartUpperZoneBAlarmLength

Integer

Alarm 39

Limit of Lower Chart Lower Zone B Limit Alarm

WELowerChartLowerZoneBAlarmLimit

Integer

Defines the limit and length values to check points in lower Zone B of the upper chart

Length of Lower Chart Lower Zone B Limit Alarm

WELowerChartLowerZoneBAlarmLength

Integer

Example

If you define alarm rule 36 with limit and length as 4 and 5 respectively, the alarm rule 36 is violated if only 4 points in a string of 5 adjacent points in the upper chart are lower than or beyond Zone B.

Graphical representation of Zone B Limit Alarm: