Function documentationControl Limit Alarm

 

Control limits are horizontal lines on SPC charts that are calculated and placed at a fixed distance (by default, +/- 3 standard deviations) above and below the centerline (mean). Alternatively, you can specify fixed control limits or calculate dynamic control limits using a query.

For alarm rule 1, the limit and length values are used for both the upper and lower charts and for both the upper and lower control limits. The data points plotted on the chart are compared to the specified control limits. For alarm rule 1, an alarm is triggered when there are <Limit> number of data points in the <Length> data point string, thereby taking the data points beyond either of the control limits. You can also use rules 20, 21, 22, or 23 with control limit alarm.

Features

Following are the alarm properties defined for Control Limit Alarm:

Alarm Name

Property Name

Parameter

Data Type

Description

Allow Upper Chart Control Limit Alarm

UpperWEControlLimitAlarmEnabled

Boolean

Enables control limit alarm for upper chart

Allow Lower Chart Control Limit Alarm

LowerWEControlLimitAlarmEnabled

Boolean

Enables control limit alarm for lower chart

Alarm 1

Alarm Limit for Control Limit

WEControlLimitAlarmLimit

Integer

Sets the limit and length values to be used to determine the alarm for the upper and lower charts and upper and lower control limits

Alarm Length for Control Limit

WEControlLimitAlarmLength

Integer

Alarm 20

Alarm Limit for Upper Chart Upper Control Limit

WEUpperChartUCLAlarmLimit

Integer

Defines the limit and length for upper control limit of the upper chart

Alarm Length for Upper Chart Upper Control Limit

WEUpperChartUCLAlarmLength

Integer

Alarm 21

Alarm Limit for Upper Chart Lower Control Limit

WEUpperChartLCLAlarmLimit

Integer

Defines the limit and length for lower control limit of the upper chart

Alarm Length for Upper Chart Lower Control Limit

WEUpperChartLCLAlarmLength

Integer

Alarm 22

Alarm Limit for Lower Chart Upper Control Limit

WELowerChartUCLAlarmLimit

Integer

Defines the limit and length for the lower control limit of the lower chart

Alarm Length for Lower Chart Upper Control Limit

WELowerChartUCLAlarmLength

Integer

Alarm 23

Alarm Limit for Lower Chart Lower Control Limit

WELowerChartLCLAlarmLimit

Integer

Defines the limit and length for the upper control limit of the lower chart

Alarm Length for Lower Chart Lower Control Limit

WELowerChartLCLAlarmLength

Integer

Example

If you use alarm rule 21 with limit and length values each as 1, the alarm rule is violated if any one point in any string of one adjacent point is beyond the upper control limit on the upper chart. A single point is marked below the lower control limit and is marked as a rule violation. The following is a graphical representation of Control Limit Alarms: