Function documentationOutside Zone C Limit Alarm Locate this document in the navigation structure

 

Alarm rule 8 is triggered when multiple points (in a series) are outside upper or lower Zone C.

For alarm rule 8, the limit and length values are used for both the upper and lower charts. The data points on the chart are checked for the specified number of points outside zone C. For alarm rule 8, an alarm is triggered when there are <Limit> number of data points in the <Length> that are outside upper or lower Zone C. You can also use other alarms 42 or 43.

Features

General guidelines to detect instability outside Zone C for different chart types are as follows:

Chart Type

Maximum Points to apply Rule

X-bar

15 consecutive points outside Zone C

Individual

Median

R-Chart when the minimum subgroup size is 4

R-Chart when the minimum subgroup size less than 4

10 consecutive points outside Zone C

Following are the alarm properties defined for Outside Zone C Limit Alarm:

Alarm Name

Property Name

Parameter Name

Data Type

Description

Allow Upper Chart Outside Zone C Limit Alarm

UpperWEOutsideZoneCAlarmEnabled

Boolean

Enables outside Zone C alarm points for upper charts

Allow Lower Chart Outside Zone C Limit Alarm

LowerWEOutsideZoneCAlarmEnabled

Boolean

Enables outside Zone C alarm points for lower charts

Alarm 8

Limit of Outside Zone C Limit Alarm

WEOutsideZoneCAlarmLimit

Integer

Sets the limit and length to check for alarms that fall outside Zone C

Length of Outside Zone C Limit Alarm

WEOutsideZoneCAlarmLength

Integer

Alarm 42

Limit of Upper Chart Outside Zone C Limit Alarm

WEUpperChartOutsideZoneCAlarmLimit

Integer

Defines the limit and length values to check for points outside Zone C of the upper chart

Length of Upper Chart Outside Zone C Limit Alarm

WEUpperChartOutsideZoneCAlarmLength

Integer

Alarm 43

Limit of Lower Chart Outside Zone C Limit Alarm

WELowerChartOutsideZoneCAlarmLimit

Integer

Defines the limit and length values to check for points outside Zone C of the lower chart

Length of Lower Chart Outside Zone C Limit Alarm

WELowerChartOutsideZoneCAlarmLength

Integer

Example

If you define alarm rule 42 with limit and length as 15 each, the alarm rule 42 is violated if only 15 points in a string of 15 adjacent points in the upper chart are outside upper or lower Zone C.

Graphical representation of Outside Zone C Limit Alarm:

This graphic is explained in the accompanying text.