Function documentationZone C Inside Limit Alarm Locate this document in the navigation structure

 

Zone C is called 1-sigma zone and is the region between zero and one standard deviation from the center line. Alarm rule 7 is triggered when multiple points (in a series) are inside upper or lower Zone C.

For alarm rule 7, the limit and length values are used for both the upper and lower charts. The data points on the chart are checked for the specified number of points in or beyond Zone C. For alarm rule 7, an alarm is triggered when there are <Limit> number of data points in the <Length> that are either in upper or lower Zone C. You can also use other alarms 40 or 41.

Features

General guidelines to detect instability within Zone C for different chart types are as follows:

Chart Type

Maximum Points to apply Rule

X-Bar

15 points in a row in Zone C above and/or below the centerline

Individual Chart

Median

R-chart when the minimum subgroup size is 4

R-chart when the minimum subgroup size is less than 4

10 successive points in Zone C above and/or below the centerline

Following are the alarm properties defined for Inside Zone C Limit Alarm:

Alarm Name

Property Name

Parameter Name

Data Type

Description

Allow Upper Chart Inside Zone C Limit Alarm

UpperWEInsideZoneCAlarmEnabled

Boolean

Enables inside Zone C alarm points for upper charts

Allow Lower Chart Inside Zone C Limit Alarm

LowerWEInsideZoneCAlarmEnabled

Boolean

Enables inside Zone C alarm points for lower charts

Alarm 7

Limit of Inside Zone C Limit Alarm

WEInsideZoneCAlarmLimit

Integer

Sets the limits and length values to check for points that fall within Zone C

Length of Inside Zone C Limit Alarm

WEInsideZoneCAlarmLength

Integer

Alarm 40

Limit of Upper Chart Inside Zone C Limit Alarm

WEUpperChartInsideZoneCAlarmLimit

Integer

Defines the limit and length values to check for points inside Zone C of the upper chart

Length of Upper Chart Inside Zone C Limit Alarm

WEUpperChartInsideZoneCAlarmLength

Integer

Alarm 41

Limit of Lower Chart Inside Zone C Limit Alarm

WELowerChartInsideZoneCAlarmLimit

Integer

Defines the limit and length values to check for points inside Zone C of the lower chart

Length of Lower Chart Inside Zone C Limit Alarm

WELowerChartInsideZoneCAlarmLength

Integer

Example

If you define alarm rule 40 with limit and length value as 19 each, the alarm rule 40 is violated if only 19 points in a string of 19 adjacent points in the upper chart are in upper and/or lower Zone C.

Graphical representation of Inside Zone C Limit Alarm:

This graphic is explained in the accompanying text.