You use the properties in the table below to display and configure the Western Electric Company (WECO) rule numbers in the lower chart of your SAP Manufacturing Integration and Intelligence (SAP MII) SPC chart. For more information about WECO rule numbers, see WECO Rules.
The following table lists the Lower Chart WECO Texts properties:
UI Text |
Parameter Name |
Data Type |
Description |
Show WECO Number Texts |
DisplayLowerWECORuleNumbers |
Boolean |
If selected, displays the WECO rule numbers on the SPC chart. |
Alarm Text Color |
LowerAlarmTextColor |
Color |
Determines the color of the alarm text |
Alarm Background Color |
LowerAlarmBackgroundColor |
Color |
Determines the color of the background of the alarm text |
Show in Reverse Coloring |
LowerShowReverseColor |
Boolean |
If selected, switches the text color with the background color |
Font Size |
LowerAlarmFontSize |
Integer |
Determines the size of the font for the alarm text |
Font Style |
LowerAlarmFontStyle |
Integer |
Sets the style of the alarm text to one of the following:
|
Alarm Text Delimiter |
LowerAlarmTextDelimiter |
String |
Sets the one-character string to be used as the delimiter for the alarm text |
Alarm [1-9] Text Abbreviation |
LowerAlarmTextAbbreviation.n [1-9] |
String (maximum of five characters) |
Sets a string to be used as a replacement for the WECO rule number. If no string is specified, the number is used. |
You can set these properties for your SPC chart template on the Lower Chart WECO Texts screen in the SAP MII Workbench and change the parameter values for individual applets through scripting.