Function documentationSpecification Limit Alarm Locate this document in the navigation structure

 

Specification limits fall on either side of the center line. The specification limit alarm rule checks for points that are beyond a specification limit.

For alarm rule 9, the limit and length values are used for both the upper and lower charts and for the upper and lower specification limits. The data points on the chart are compared to the specification limits. For alarm rule 9, an alarm is triggered when there are <Limit> number of data points in the <Length> that occur on either side of the specification limits. You can also use alarms 44, 45, 46, or 47.

Features

Following are the alarm properties defined for Specification Limit Alarm:

Alarm Name

Property Name

Parameter

Data Type

Description

Allow Upper Chart Specification Limit Alarm

UpperWESpecificationLimitAlarmEnabled

Boolean

Enables specification limit alarms for upper charts

Allow Lower Chart Specification Limit Alarm

LowerWESpecificationLimitAlarmEnabled

Boolean

Enables specification limit alarms for lower charts

Alarm 9

Alarm Limit for Specification Limit

WESpecificationLimitAlarmLimit

Integer

Sets the limit and length values to check for alarms that are beyond specification limits

Alarm Length for Specification Limit

WESpecificationLimitAlarmLength

Integer

Alarm 44

Alarm Limit for Upper Chart Upper Spec. Limit

WEUpperChartUSLAlarmLimit

Integer

Defines the limit and length values to check for points outside upper specification limits of upper chart

Alarm Length for Upper Chart Upper Spec. Limit

WEUpperChartUSLAlarmLength

Integer

Alarm 45

Alarm Limit for Upper Chart Lower Spec. Limit

WEUpperChartLSLAlarmLimit

Integer

Defines the limit and length values to check for points outside lower specification limits of upper chart

Alarm Length for Upper Chart Lower Spec. Limit

WEUpperChartLSLAlarmLength

Integer

Alarm 46

Alarm Limit for Lower Chart Upper Spec. Limit

WELowerChartUSLAlarmLimit

Integer

Defines the limit and length values to check for points outside upper specification limits of lower chart

Alarm Length for Lower Chart Upper Spec. Limit

WELowerChartUSLAlarmLength

Integer

Alarm 47

Alarm Limit for Lower Chart Lower Spec. Limit

WELowerChartLSLAlarmLimit

Integer

Defines the limit and length values to check for points outside lower specification limits of lower chart

Alarm Length for Lower Chart Lower Spec. Limit

WELowerChartLSLAlarmLength

Integer

Example

If you define alarm rule 44 with limit and length as 1 each, the rule is violated if only 1 point in a string of 1 adjacent point is beyond the upper specification limit on the upper chart. In the below illustration, one violation is for a point above the upper specification limit, while the other is for a point below the lower specification limit.

Graphical representation of Specification Limit Alarm

This graphic is explained in the accompanying text.