Function documentationiSPCChart Alarm Properties Locate this document in the navigation structure

 

You use the properties in the following table to configure alarms for your SAP Manufacturing Integration and Intelligence (SAP MII) statistical process control (SPC) charts.

Features

The following table lists alarm properties:

Property Name

Parameter Name

Data Type

Allow Upper Control Limit Alarm

UpperWEControlLimitAlarmEnabled

Boolean

Allow Lower Control Limit Alarm

LowerWEControlLimitAlarmEnabled

Boolean

Alarm Limit for Control Limit

WEControlLimitAlarmLimit

Integer

Alarm Length for Control Limit

WEControlLimitAlarmLength

Integer

Allow Upper Specification Limit Alarm

UpperWESpecificationLimitAlarmEnabled

Boolean

Allow Lower Specification Limit Alarm

LowerWESpecificationLimitAlarmEnabled

Boolean

Alarm Limit for Specification Limit

WESpecificationLimitAlarmLimit

Integer

Alarm Length for Specification Limit

WESpecificationLimitAlarmLength

Integer

Allow Upper Alternating Limit Alarm

UpperWEAlternatingAlarmEnabled

Boolean

Allow Lower Alternating Limit Alarm

LowerWEAlternatingAlarmEnabled

Boolean

Limit of Alternating Limit Alarm

WEAlternatingAlarmLimit

Integer

Length of Alternating Limit Alarm

WEAlternatingAlarmLength

Integer

Allow Upper Run Limit Alarm

UpperWERunAlarmEnabled

Boolean

Allow Lower Run Limit Alarm

LowerWERunAlarmEnabled

Boolean

Limit of Run Limit Alarm

WERunAlarmLimit

Integer

Length of Run Limit Alarm

WERunAlarmLength

Integer

Allow Upper Trend Limit Alarm

UpperWETrendAlarmEnabled

Boolean

Allow Lower Trend Limit Alarm

LowerWETrendAlarmEnabled

Boolean

Alarm Limit of Trend Limit

WETrendAlarmLimit

Integer

Alarm Length of Trend Limit

WETrendAlarmLength

Integer

Allow Upper Sigma Difference Limit Alarm

UpperWESigmaDifferentAlarmEnabled

Boolean

Allow Lower Sigma Difference Limit Alarm

LowerWESigmaDifferentAlarmEnabled

Boolean

Limit of Sigma Difference Limit Alarm

WESigmaDifferentLimitAlarmLimit

Integer

Length of Sigma Difference Limit Alarm

WESigmaDifferentAlarmLength

Integer

Allow Upper Zone A Limit Alarm

UpperWEZoneAAlarmEnabled

Boolean

Allow Lower Zone A Limit Alarm

LowerWEZoneAAlarmEnabled

Boolean

Limit of Zone A Limit Alarm

WEZoneAAlarmLimit

Integer

Length of Zone A Limit Alarm

WEZoneAAlarmLength

Integer

Allow Upper Zone B Limit Alarm

UpperWEZoneBAlarmEnabled

Boolean

Allow Lower Zone B Limit Alarm

LowerWEZoneBAlarmEnabled

Boolean

Limit of Zone B Limit Alarm

WEZoneBAlarmLimit

Integer

Length of Zone B Limit Alarm

WEZoneBAlarmLength

Integer

Allow Upper Inside Zone C Limit Alarm

UpperWEInsideZoneCAlarmEnabled

Boolean

Allow Lower Inside Zone C Limit Alarm

LowerWEInsideZoneCAlarmEnabled

Boolean

Limit of Inside Zone C Limit Alarm

WEInsideZoneCAlarmLimit

Integer

Length of Inside Zone C Limit Alarm

WEInsideZoneCAlarmLength

Integer

Allow Upper Outside Zone C Limit Alarm

UpperWEOutsideZoneCAlarmEnabled

Boolean

Allow Lower Outside Zone C Limit Alarm

LowerWEOutsideZoneCAlarmEnabled

Boolean

Limit of Outside Zone C Limit Alarm

WEOutsideZoneCAlarmLimit

Integer

Length of Outside Zone C Limit Alarm

WEOutsideZoneCAlarmLength

Integer

You set these properties for your SPC chart template on the Alarmsscreen in the SAP MII Workbench and change the parameter values for individual applets using scripting.