Show TOC

Function documentationiChart Limit Texts Locate this document in the navigation structure

 

You use the following properties to configure and display the numerical values of the specification limits on a line chart and in its legend.

Integration

You use these properties with the iChart Specification Limits properties.

Features

The following table lists the specification limit text properties for a line chart.

UI Name

Limit Type

Property Name

Description

Show Limit Text

Upper Limit

Center Line

Lower Limit

ShowUpperLimitText

ShowCenterLineText

ShowLowerLimitText

If you select the checkboxes, the specification limit texts are displayed on the chart for the limit type.

Horizontal Text Alignment

Upper Limit

Center Line

Lower Limit

UpperLimitHorizontalTextAlignment

CenterLineHorizontalTextAlignment

LowerLimitHorizontalTextAlignment

Displays the spec. limit texts to the left (L), center (C), or right (R) of the limit

Vertical Text Alignment

Upper Limit

Center Line

Lower Limit

UpperLimitVerticalTextAlignment

CenterLineVerticalTextAlignment

LowerLimitVerticalTextAlignment

Displays the spec. limit texts based on the following options:

  • AUTO

    The system determines whether to display the texts above or below the limit based on available space.

  • U

    The system displays the texts above the limit.

  • D

    The system displays the text below the limit.

Font Size

Upper Limit

Center Line

Lower Limit

UpperLimitFontSize

CenterLineFontSize

LowerLimitFontSize

Determines the font size of the spec. limit texts for each limit type

Font Style

Upper Limit

Center Line

Lower Limit

UpperLimitFontStyle

CenterLineFontStyle

LowerLimitFontStyle

Determines the font style of the spec. limit texts for each limit type

Reverse Coloring

Upper Limit

Center Line

Lower Limit

UpperLimitReverseColoring

CenterLineReverseColoring

LowerLimitReverseColoring

Switches the color of the background with the color of the text for each limit type

Activities

You set these properties for your line chart on the Limit Texts screen in the SAP MII Workbench and change the parameter values for individual applets using scripting.