Check Configuration
You can use the CT520
hook point activity to compare the components in the build history of an SFC number to its BOM to ensure SFCs have the correct number of assembled components.
If operators are using this activity with multiple SFC numbers or process lots, the failure of one SFC number in the group causes the system to fail the entire group.
The CT520
hook point activity does not support processing partial quantities of a non-serialized SFC.
Note
The CT520
hook point activity is typically used at a final step to ensure all required components have been assembled.
Note
This hook point activity works only if the SFC number is on a Production
routing.
The activity ignores the following component types when executed:
Phantom
Co-product
By-product
This activity is commonly used with the PRE_START
, PRE_COMPLETE
, and POST_COMPLETE
hook points. If this activity is executed at PRE_START
, it checks for components at the previous operations only. If this activity is executed at PRE_COMPLETE
or POST_COMPLETE
, it checks for components at the current operation and all previous operations.
CHECK_OPERATIONS
, CHECK_CURRENT_OPER_ONLY
, and CHECK_ALL_COMP_LAST_OPER
work in conjunction to specify which operations to check for MISSING
, EXCESS
, TEST_PART
, and NON_BOM
. Their precedence is as follows:
CHECK_OPERATIONS
(Ignores the other two rules listed)
CHECK_CURRENT_OPER_ONLY
CHECK_ALL_COMP_LAST_OPER
The following table describes rules and settings that you can change for this activity in Activity Maintenance
:
Rule | Setting |
|---|---|
| User-defined: Enter a comma-delimited list of assembly operations. Checks only the specified list of assembly operations. Ignores Blank (default): Checks all operations on the current routing up to the current step. |
|
|
|
The system ignores this rule if either End of the note. |
| This rule is used in conjunction with the
Setting this rule to End of the caution.
|
|
|
|
|
|
|
|
|