Show TOC

Procedure documentationSetting Up Operation and Work Center PODs Locate this document in the navigation structure

Prerequisites

You have defined the needed lists in List Maintenance activity (see List Maintenance).

Procedure

  1. On the initial screen of POD Maintenance, specify the POD type and enter the name of this POD.

  2. On the Main tab page, enter the required information. The following table describes fields requiring explanation:

    Field

    Description

    Status

    If enabled, allows you to use this POD on the shop floor

    NC Client

    The nonconformance client for this POD

    Use NC Client Maintenance to define the behavior and look of the nonconformance-related buttons (see NC Client Maintenance).

    Real-Time Message Display

    Determines how the real-time messages are displayed in the POD:

    None: Real-time messages are not displayed in the POD.

    Icon: Displays the Real-Time Message Display icon each time a real-time message arrives at the POD.

    Special Instruction Display

    The special instruction that is defined for the operation or routing operation on the POD:

    None: Does not display the special instruction

    Info Message: Displays the special instruction in the POD Message Bar upon starting an SFC number

    Popup: Displays the special instruction in a dialog box window upon starting an SFC number

    Session Timeout (mins)

    The number of minutes the POD can be inactive before the system logs out the operator

    The default value is 30 minutes.

  3. On the Buttons tab page, define the buttons or button groups that appear in the POD (see Defining POD Buttons and Button Groups)

  4. On the Layout tab page, specify the layout for your POD:

    • 1 Panel Vertical Layout (with Popover): Displays one panel in the POD with a popover panel from the right

    • 3 Panel Horizontal Layout (with Popover) (default): Displays one panel in the upper part of the POD, and two panels in the lower part of the POD with a popover panel from the lower right

    • 3 Panel Vertical Layout (with Popover): Displays one panel in the left part of the POD, and two panels in the right part of the POD with a popover panel from the lower right

    • 6 Panel Horizontal Layout: Displays two panels in the upper part of the POD, one panel in the middle, and three panels in the lower part of the POD

    • 6 Panel Vertical Layout: Displays two panels in the left part of the POD, and four panels in the right part of the POD

  5. Configure plug-ins that are displayed in various panels on the POD:

    Column

    Description

    Panel

    Displays the letter from the graphic that identifies this panel

    Type

    Displays the type of layout specified for the panel: Popover, Popup, or Fixed

    Default Plug-In

    The activity ID associated with the default plug-in for the panel

    This field is grayed out when the value is Popup or Popover.

    Note that default plug-ins only apply to fixed panels

    Other Plug-Ins

    Allows you to associate one or more additional plug-ins to the panel in addition to the default plug-in identified in the Activity ID column by inserting new rows in the table on the Other Plug-In Details screen.

    Note that this plug-in replaces the plug-in that currently occupies the panel when the operator initiates an activity that requires the panel. When the activity is complete and the system or the user closes this plug-in, the plug-in that previously occupied the panel is redisplayed.

  6. On the Options tab page, define what the system displays in the lower half of the POD screen:

    Field

    Description

    Main Input

    The label for the Operation or SFC field on the Operation POD. This field label can be updated to a customer value to match their manufacturing process.

    Default value: I18N[sfc.default.LABEL] I

    18N is an abbreviation for the word internationalization. The text between the brackets is the identifier for the label. If you want your label to be internationalized, you must use the format of the default value with the label identifier you want.

    Note that this field applies to Operation POD only.

    Browse Work List

    An appropriate Worklist list (should display New and In Queue status) that has been configured in List Maintenance. The list appears when the operator clicks the browse icon next to the Main Inputfield.

    Note that this field applies to Operation POD only.

    POD Work List

    An appropriate Worklist list (should display Active and Complete Pending status) that has been configured in List Maintenance. The list appears when the operator clicks the browse icon next to the Main Input field.

    Assemble List

    An appropriate Assemble list that has been configured in List Maintenance

    Operation List

    An appropriate Operation list that has been configured in List Maintenance

    Note that this field applies to Work Center POD only.

    DC Collect List

    An appropriate DC Collect list that has been configured in List Maintenance

    Tool List

    An appropriate Tool list that has been configured in List Maintenance

    Work Instruction List

    An appropriate Work Instruction list that has been configured in List Maintenance

    DC Entry List

    An appropriate DC Entry list that has been configured in List Maintenance

    Default Operation

    The name of the operation the POD displays in the Operation field when an operator opens the POD

    If you leave it blank, no operation is displayed. Supplying this value eliminates the need for the operator to enter it every time he or she opens the POD.

    Note that this field applies to Operation POD only.

    Operation Can Be Changed

    If selected, allows operators to change the operation the POD displays in the Operation field

    Note that this field applies to Operation POD only.

    Default Resource

    The name of the resource the POD displays in the Resource field when an operator opens the POD

    If you leave it blank, no resource is displayed. Supplying this value eliminates the need for the operator to enter it every time he or she opens the POD.

    Resource Can Be Changed

    If selected, allows operators to change the resource the POD displays in the Resource field

    Note that this field applies to Operation POD only.

    SFC Queue Button ID

    The activity assigned to a POD button that is executed when the user enters a value in the SFC field and tabs out of the field when an SFC number is In Queue at the entered operation.

    Note that the button ID should be a single activity not a group activity. The button ID must begin with a letter.

    Note that this field applies to Operation POD only.

    SFC In Work Button ID

    The activity assigned to a POD button that is executed when the user enters a value in the SFC field and tabs out of the field when an SFC number is In Work at the entered operation.

    Note that the button should be a normal button not a group button. The button ID must begin with a letter.

    Note that this field applies to Operation POD only.

    Session Info Line 1

    The first 'session info' line that is displayed in the POD:

    None: Indicates that nothing is displayed

    Completed: Indicates that the number of SFC numbers completed at the current operation and/or resource is displayed.

    Nonconformed: Indicates that the number of SFC numbers nonconformed and dispositioned at the current operation and/or resource is displayed.

    Active: Indicates that the number of active SFC numbers/SO/PL in work at the current operation and resource is displayed

    In Queue: Indicates that the number of SFC numbers in queue at the current operation and/or resource is displayed.

    Note that this field applies to Operation POD only.

    Session Info Line 2

    The second 'session info' line that is displayed in the POD

    Show Operation First

    If selected, displays the Operation field to the left of the Resource field

    Note that this field applies to Operation POD only.

    Show Quantity

    If selected, displays the Quantity field in the Operation and SFC POD Selection plug-ins

    Note that this field applies to Work Center POD only.

  7. If required, specify printers for specific document types on the Printers tab page (see Document Maintenance).

  8. On the Custom Data tab page, enter values in the fields defined for this POD in Custom Data Maintenance (see Custom Data Maintenance).

  9. Save your entries.