Show TOC

Background documentationSerialization Rules Locate this document in the navigation structure

 

This group controls how data is handled during SFC number serialization and splits (see SFC Number).

System Rule

Description

Copy Activity Log Records

If set to true, copies the Activity Log records from the original SFC number to the new SFC numbers that result from serialization, split, or relabel.

Can override at: site, material

Copy DC Data

If set to true (default), copies or moves the data collection (DC) data records from the original SFC number to the new SFC numbers that result from a serialization, split, or relabel

Can override at: site

Note that Post Split/Serialize - Copy DC Data (DC999) must be hooked to the POST_SPLIT and/or POST_SERIALIZE hook point at the site level.

Copy NC Data

If set to true, copies the nonconformance (NC) data records from the original SFC number to the new SFC numbers that result from a serialization or split

Can override at: site

Caution Caution

When the SFC number is panelized and the location value in the NC data matches one of the location values on the panel, the system moves the NC data to the new SFC number that corresponds to that piece, regardless of the setting of this system rule. If the location value in the NC data does not match one of the location values on the panel, the system follows the setting of this system rule.

End of the caution.

Note that Post Split/Serialize - Copy DC Data (NC999) must be hooked to the POST_SPLIT and/or POST_SERIALIZE hook point at the site level.

Status of an Empty Lot SFC Number

Determines the status that the system assigns to SFC numbers in a lot (in a nonserialized SFC number) when all the SFC numbers have been serialized or split

Set to any valid SFC number status (see SFC Number).

Default: 408, which corresponds to Invalid

Can override at: site, material