Show TOC

 Coil Delivery Check

Use

When the reel calculation attempts to find a suitable reel, the system first reads the Coil delivery indicator to determine whether the length of material can be handled in the form of a coil.

Prerequisites

  • You have selected the Coil delivery indicator in the cable material master.

  • In Customizing for the Reel Calculation, y ou have made the following settings:

    • You have defined the maximum permissible cable length and the maximum permissible cable weight for coil delivery, by choosing Set Plant Data , and making the relevant entries in the Coil Check group box.

    • You have entered valid reel categories for the reel calculation, by choosing Start of the navigation path Set Plant Data Next navigation step Reel Categories End of the navigation path .

    • You have entered the reel category to be used as a coil, by choosing Set Plant Data , and making the relevant entry in the Coil group box, and you have assigned the corresponding reel type.

Features

If the material master indicates that coil delivery is possible, the system uses the Customizing settings to check whether a coil is permitted for the length and determined weight of the cable material ( net weight in the cable material master). If it is, the system assigns the reel category and reel type automatically in line with the settings.