 Data from the Routing

If a routing exists for the material to be produced, components can be assigned to specific operations in the routing.

If necessary, the following indicator is copied from the operations in a routing:

  • Backflushing : If the Backflushing indicator is set for a component, the withdrawal posting for the component is carried out automatically with the completion confirmation of the operation to which the component is assigned. You can set this indicator on the General data screen of the component (see Changing Component Data .)

Note Note

The Backflushing indicator can also be set in the work center and in the material master (see Goods Movements During Confirmation ).