In the
Results Recording
component, you record and process results for inspection characteristics. The
inspection lot
is the reference object in results recording.
The recorded inspection results document the quality of the inspected product, and provide the basis for creating batch specifications and inspection certificates. You can use the recorded result data to make evaluations for quality control purposes.
In addition to results recording based on characteristics, you can also use process-optimized results recording to record inspection results for all operations, inspection points or lots depending on your requirements. You can also process defect data using the defects recording function.
To be able to record inspection results, the following conditions must be met:
Inspection specifications
(task list or material specification)
are assigned to the inspection lot
Note
If you inspect according to configuration or batch, the inspection specifications are changed correspondingly from the task list or material specification. For more information, see Editing the Inspection Setup .
Note
You can also manage multiple specifications in the inspection specifications. These multiple specifications can then be used in inspection processing to determine batch suitability. For more information, see Multiple Specifications .
Characteristics have been created
Sample calculation has been carried out
Note
The processing status of an inspection lot is documented by the inspection lot status. For more information about the inspection lot status, see Status Management for Inspection Lots .
Using this component, you can:
Process results for an operation
Process results for multiple samples
Process results for different inspection point categories :
For an inspection point during production
For a physical sample
For equipment
For a functional location
Process results for a delivery in sales and distribution
Display individual results for a characteristic (confirmation number)
Decide to accept or reject the inspection characteristics
Calculate summarized characteristic values
Record defect data straight from the results recording function
Print inspection results