Entering content frame

Background documentation ToolBarInputField Locate the document in its SAP Library structure

This UI element makes a InputField available in a ToolBar. It enables the user to enter or display a single-line text in the toolbar.

Note

To ensure Accessibility a check is made during design time that the label property has been specified.

If no label has been set, and no descriptive text has been specified for the appropriate bound context element in the ABAP Dictionary, a check is made for the tooltip property.

 

Runtime Class

CL_WD_TOOLBAR_INPUT_FIELD

 

Properties in the View Designer

Name

Type

Initial Value

Bindable

ID

STRING

(automatic)

No

alignment

WDUI_INPUT_FIELD_ALIGNMENT

auto

Yes

collapsible

WDY_BOOLEAN

false

Yes

enabled

WDY_BOOLEAN

true

Yes

labelText

Text

 

Yes

length

I

20

Yes

passwordField

WDY_BOOLEAN

false

Yes

readOnly

WDY_BOOLEAN

false

Yes

state

WDUI_STATE

normal

Yes

textDirection

WDUI_TEXT_DIRECTION

inherit

Yes

tooltip

Text

 

Yes

value

Text

 

mandatory

visible

WDUI_VISIBILITY

visible

Yes

width

STRING

 

Yes

 

Events in the View Designer

Name

onEnter

Note

Further properties that can be inherited are defined in the associated higher-level class.  The associated interface elements are:

      AbstractInputField  

      UIElement

      ViewElement

Dynamic Programming

For dynamic programming the same properties, events, and aggregations are provided in the View Designer. Bear in mind the different spellings.

Dynamic Programming of Properties

View Designer Name

Runtime Name

Type

alignment

ALIGNMENT

WDUI_INPUT_FIELD_ALIGNMENT

 alignment: auto

CL_WD_TOOLBAR_INPUT_FIELD=>E_ALIGNMENT-AUTO

 alignment: beginOfLine

CL_WD_TOOLBAR_INPUT_FIELD=>E_ALIGNMENT-BEGIN_OF_LINE

 alignment: center

CL_WD_TOOLBAR_INPUT_FIELD=>E_ALIGNMENT-CENTER

 alignment: endOfLine

CL_WD_TOOLBAR_INPUT_FIELD=>E_ALIGNMENT-END_OF_LINE

 alignment: forcedLeft

CL_WD_TOOLBAR_INPUT_FIELD=>E_ALIGNMENT-FORCED_LEFT

 alignment: forcedRight

CL_WD_TOOLBAR_INPUT_FIELD=>E_ALIGNMENT-FORCED_RIGHT

collapsible

COLLAPSIBLE

WDY_BOOLEAN

enabled

ENABLED

WDY_BOOLEAN

labelText

LABEL_TEXT

WDY_MD_TRANSLATABLE_TEXT

length

LENGTH

I

passwordField

PASSWORD_FIELD

WDY_BOOLEAN

readOnly

READ_ONLY

WDY_BOOLEAN

state

STATE

WDUI_STATE

 state: normal

CL_WD_TOOLBAR_INPUT_FIELD=>E_STATE-NORMAL

 state: required

CL_WD_TOOLBAR_INPUT_FIELD=>E_STATE-REQUIRED

textDirection

TEXT_DIRECTION

WDUI_TEXT_DIRECTION

 textDirection: inherit

CL_WD_TOOLBAR_INPUT_FIELD=>E_TEXT_DIRECTION-INHERIT

 textDirection: ltr

CL_WD_TOOLBAR_INPUT_FIELD=>E_TEXT_DIRECTION-LTR

 textDirection: rtl

CL_WD_TOOLBAR_INPUT_FIELD=>E_TEXT_DIRECTION-RTL

tooltip

TOOLTIP

WDY_MD_TRANSLATABLE_TEXT

value

VALUE

WDY_MD_TRANSLATABLE_TEXT

visible

VISIBLE

WDUI_VISIBILITY

 visible: none

CL_WD_TOOLBAR_INPUT_FIELD=>E_VISIBLE-NONE

 visible: visible

CL_WD_TOOLBAR_INPUT_FIELD=>E_VISIBLE-VISIBLE

width

WIDTH

STRING

 

Dynamic Programming of Events

View Designer Name

Runtime Name

onEnter

ON_ENTER

Example

You can find an example of this UI element in the system in the Web Dynpro application, WDR_TEST_UI_ELEMENTS.

 

 

Leaving content frame