Entering content frame

Procedure documentation Transporting Monitor Sets and Monitor Definitions Locate the document in its SAP Library structure

Use

You can transport monitor sets to other systems in your transport landscape. This is only necessary for the monitor sets that you create yourself, as the monitor sets provided by SAP are already available in all SAP systems.

If you want to use the definitions of individual monitors in other SAP systems, we recommend that you export them as an XML file and then import them. To do this, you must store the monitor definition in a file in XML format in the source system; this is then imported into the target system. This exchange is faster, as no SAP transports must be created. You can also distribute existing monitor definitions quickly over the Internet or a file server in XML format.

Prerequisites

To transport a monitor set or a monitor definition, you must first activate the maintenance functions.

Procedure

Transport a Monitor Set

The transport of monitor sets uses the SAP transport mechanism.

  1. To do this, choose CCMS ® Control/Monitoring ® Alert Monitor, or call transaction RZ20. The system displays the CCMS Monitor Sets screen.
  2. Choose Extras ® Activate Maintenance Functions.
  3. Choose the monitor set that you want to transport, and choose Transport Monitor Set (This graphic is explained in the accompanying text).
  4. Enter a Workbench request with the desired target system.

For an overview of how to transport objects between SAP systems, see Structure linkTransport Management System (BC-CTS-TMS).

Transport a Monitor Definition

The transport of a monitor definition uses the export and import of the definition in XML format.

  1. To do this, choose CCMS ® Control/Monitoring ® Alert Monitor, or call transaction RZ20. The system displays the CCMS Monitor Sets screen.
  2. Choose Extras ® Activate Maintenance Functions.
  3. Choose the monitor for which you want to export the definition and then choose Monitor ® Display Monitor Definition.
  4. The system displays the Display Monitor Definition screen. Choose Monitor Definition ® Export. Enter a file name and path to which you have access from the target system.
  5. Switch to the target system, and choose CCMS ® Control/Monitoring ® Alert Monitor, or call transaction RZ20. The system displays the CCMS Monitor Sets screen.
  6. Choose Extras ® Activate Maintenance Functions.
  7. Create a new monitor. To do this, select the desired monitor set and choose Create (This graphic is explained in the accompanying text).
  8. Choose Monitor Definition ® Import and specify the file name and path entered above.

Caution

If the monitor definition already exists, this is overwritten by the import of a definition.

See also:

Creating and Editing Monitor Sets

Leaving content frame