To activate error handling in the Monitoring and Error Handling
transaction, a standard error handling application is required. The standard error handling application delivered with the SAP Application Interface Framework is called AIF
.
Recommendation
As an initial step, it is recommended that you check if the AIF
application is correctly defined and, if it does not exist, create and maintain it.
Maintain error handling applications in Customizing for SAP Application Interface Framework
(transaction code /AIF/CUST
) under .
Choose Maintain Application
and check that there is an entry for application ID AIF
. If the application ID AIF
does not exist, create it with the following settings:
Field | Value |
---|---|
Short description | AIF Application |
Table of maintaining Appl. key fields | /AIF/T_INF_TBL |
Entry Data Facade | /AIF/CL_AIF_ENTRY_DATA_FACADE |
Module | /AIF/SAPLAIF_SP_SSC |
Screen number | 9101 |
Appl. log context structure name | /AIF/BAL_CONTEXT |
Action handler | /AIF/CL_AIF_ACTION_HANDLER |
Program Name |
|
GUI Status |
|
URL for Interface Monitor |
|
Image object name for Interface Monitor | /AIF/SAP_NETWEAVER_MONITOR |
Make sure you select the application AIF
and choose Maintain Application Specific Key Fields
. There should be the following three entries:
Position sequence no | Field | Value |
---|---|---|
1 | Work Field | P_NS |
Field Name | NS | |
Data Element | /AIF/NS | |
Is field select-option? |
| |
2 | Work Field | S_IFNAME |
Field Name | IFNAME | |
Data Element | /AIF/IFNAME | |
Is field select-option? | X | |
3 | Work Field | P_IFVERS |
Field Name | IFVER | |
Data Element | /AIF/IFVERSION | |
Is field select-option? |
|
Make sure that you select AIF
and choose Register Functions
. There should be the following six entries:
Function | View Code | Field | Value |
---|---|---|---|
CANCEL | 1 | Sequence Number | 2 |
Button Description | Cancel | ||
Button tool tip | Cancel | ||
Icon | @3J@ | ||
MONI | 1 | Sequence Number | 3 |
Button Description | (blank) | ||
Button tool tip | Integration Engine: Monitor | ||
Icon | @16@ | ||
QRFC | 1 | Sequence Number | 4 |
Button Description | (blank) | ||
Button tool tip | QRFC Monitor | ||
Icon | @6P@ | ||
RESTART | 1 | Sequence Number | 1 |
Button Description | Restart | ||
Button tool tip | Restart | ||
Icon | @15@ | ||
SLOGS | 3 | Sequence Number | 1 |
Button Description | (blank) | ||
Button tool tip | Display Error Message(s) | ||
Icon | @DR@ | ||
TRACELEV | 1 | Sequence Number | 5 |
Button Description | (blank) | ||
Button tool tip | Maintain Trace Level | ||
Icon | @4H@ |
Make sure that you select AIF
and choose Exclude Function from Appl. Toolbar
. There should be no entries.