CL_ISU_EDM_SETTLSTEP_0019
Class derived from CL_ISU_EDM_SETTLSTEP
The process method adds the total load shapes of the transferred grids (input parameter 01) for the settlement period, taking into account the hierarchy. The total load shape (including lower-level grids) exists as result parameter 01 for every higher-level grid. If a grid does not have any lower-level grids, the result profile for this grid is the total load shape.
Only one total profile is allowed per grid as result parameter. Processing is terminated if a total load shape for a lower-level grid is not transferred.

Class CL_ISU_EDM_SETTLSTEP_0019 can be derived.