How to change a BOM group:
The Change BOM group initial screen appears. Initial screen.
If a user parameter for the Usage field is defined as a default value in your user master record, the system enters either this default value or the last value entered.
If you make an entry in the BOM group field, the system ignores any entries you make for the Material and Usage.
If you want to change the BOM group historically, enter a change number. The system determines the valid-from date from the change master record.
If your data is correct, you see the Summarized BOM screen.
Any change you make on this screen affects all the alternatives assigned to the BOM group.
You can, for example:
– enter a new item
If you enter a new item, set the indicator for the alternative for which the new item is valid.
– change the item quantity
In this case, the changed quantity applies to all alternatives to which the item is assigned.
If you only want to change the item quantity for some of the alternatives that use it, create the item with the new item quantity and assign it to the alternatives concerned.
You see the Item in alternative(s) screen, on which you can edit the Assignment field for each alternative of the BOM group.