
Plan Input Processing for Measured Values in the EWB
Use
You must plan input processing at the inspection planning stage to ensure that the system automatically processes your measured values according to your specifications during results recording. As a result, during results recording, the BAdI that has been defined for the inspection characteristic is run and the input value is processed.
In the Engineering Workbench, you can plan the data for input processing on the characteristic detail screen and on the overview screen (tab page Quantitative Data) of an inspection plan. You can access an existing
master inspection characteristic and use it during this planning stage.
Prerequisites
In Customizing, the instance of the BAdI parameter for the input-processing key must be defined. Thereby, you define how the input value (measured value) is to be processed.
Procedure
|
in the inspection characteristic overview, |
on the characteristic details screen, |
|
you can do the following:
|
select the inspection characteristic that you wish to use input processing for, and choose Details. On the Control Indicators... tab page, set the radio button for input processing. The system automatically switches to the detail screen for the quantitative data. You can now enter the input-processing key.
If the control indicator Input Processing is not set, you cannot enter a key for input processing on the characteristic overview screen. |

The radio buttons Calculated Characteristic and Input Processing cannot both be set at the same time. This means:
When the radio button Calculated Characteristic is set, you cannot set the radio button Input Processing and you cannot enter the input-processing key.
When you set the radio button Calculated Characteristic, the radio button Input Processing and the input-processing key are reset by the system.

If the Input Processing radio button is not set, the field for input processing in the quantitative data is not visible.
If the Input Processing radio button is set, you must enter an input-processing key.
If the radio button Input Processing is reset, the input processing key is deleted automatically by the system.
If the included master inspection characteristic is an incomplete copy model, you must enter an input-processing key in the plan if the Input Processing radio button is set.
Result
As a result, during results recording, the BAdI method that has been assigned to this inspection characteristic is run and the input value is processed.
See also:
Plan Input Processing for Measured Values in the Inspection Plan
Plan Input Processing for Non-Classed Measured Values in the Master Inspection Characteristic
Input Processing of Non-Classed Measured Values in Results Recording