The system opens a new session and displays an overview of your spool requests.
You can now see the sample-drawing instruction. This contains the physical-sample drawing text, partial samples to be created, and the distribution of samples to laboratories.
Partial sample 1 is used for operation 0010 from the inspection plan (visual inspection) and incorporates all 1000 units/10 packs of the inspection lot. The visual inspection takes place at the work center for goods receipt inspection I.
Partial sample 2 is used for operation 0020 from the inspection plan (mechanical inspection) and incorporates 5 units. The mechanical inspection takes place at the work center for goods receipt inspection II.
Partial sample 0 and partial sample 2 are used in operation 0020 for the destructive inspection of the characteristic Tension test with test strength that comes from the material specification.
The system displays the inspection instruction. You have to scroll through several pages to view the entire inspection instruction.
The inspection instruction in this form example contains all of the specifications from the inspection plan in detail and the sample sizes determined on the basis of the inspection lot data and quality level.