Fields
DECIMALS_O , EDIT_MASK , EXPONENT , NO_SIGN and ROUND correspond to WRITE additions DECIMALS , USING EDIT MASK , EXPONENT , NO-SIGN and ROUND . For information on combining these fields with fields CURRENCY and QUANTITY (for WRITE: UNIT ), see the F1 help for the WRITE edit option.Field name |
Comp. type |
Dtype(length) |
Value range |
Use | |||
DECIMALS_O |
LVC_DECMLS |
Char(6) |
initial, natural number |
Relevant only if no currency field is assigned to the field and if CURRENCY has a value. The value in this field determines the number of digits to be displayed after the comma. | |||
DECMFIELD |
LVC_DFNAME |
Char(30) |
SPACE, field name of output table |
Defining the digits after the comma on a row-by-row basis. You can use an additional field in the output table to determine how many digits are to be displayed after the comma in each row. | |||
EDIT_MASK |
LVC_EDTMSK |
Char(60) |
SPACE, conv (conversion exit) |
If you set a conversion exit (for example, conv = ' ==ALPHA ' for function module CONVERSION_EXIT_ALPHA_OUTPUT ), you enforce output conversion for the associated output field. (See also F1 help for WRITE edit option USING EDIT MASK) .See also: Using the Conversion Exit | |||
EXPONENT |
LVC_EXPONT |
Char(3) |
initial, integer |
Determines a fixed exponent for the field. The field must be of internal type F. (See also F1 help for WRITE edit option EXPONENT ). | |||
ICON |
LVC_ICON |
Char(1) |
SPACE, 'X' |
If this field is set, the column contents of the output table are output as an icon. The column contents must consist of valid icon strings ( @xx@ or @xx\Q <Quickinfo> @ ).You should consider the problem of printing icons. | |||
JUST |
LVC_JUST |
Char(1) |
SPACE, 'R', 'L','C' |
Relevant only to fields of data type CHAR or NUMC .Justifications:
How the column header is justified, depends on how the column contents are justified. You cannot justify the column header separately. | |||
LZERO |
LVC_LZERO |
Char(1) |
SPACE, 'X' |
Relevant only to fields of data type NUMC . In the default setting, the ALV Grid Control displays these fields right justified without leading zeros. If you set LZERO , leading zeros are displayed. | |||
NO_SIGN |
LVC_NOSIGN |
Char(1) |
SPACE, 'X' |
Relevant only to value fields. If you set NO-SIGN , values are displayed without signs (see also F1 help for the WRITE edit options). | |||
NO_ZERO |
LVC_NOZERO |
Char(1) |
SPACE, 'X' |
If NO_ZERO is set, no zeros are displayed for initial value fields. The cell remains empty. | |||
ROUND |
LVC_ROUND |
Char(10) |
initial, natural number |
Displaying a value of type P scaled by the power of ten. For positive ROUND values, the ALV Grid Control moves the comma to the left; otherwise, it moves the comma to the right. (See also F1 help for the WRITE edit options) | |||
ROUNDFIELD |
LVC_RNDFN |
Char(30) |
|
Defining scaled output on a row-by-row-basis. You can use an additional field in the output table to determine how the relevant field is scaled in each row. | |||
SYMBOL |
LVC_SYMBOL |
Char(1) |
SPACE, 'X' |
If this field is set, the column contents are displayed as a symbol. The column contents of the internal table must consist of valid symbol signs. The caller should consider the problem of printing symbols. (It is usually possible to print symbols, but they may not be output correctly depending on the printer configuration). | |||