Show TOC
copy
models
Definition
List field, in which you can select an option
for identifying the master inspection characteristic.
Dependencies
- If you select the option "Complete copy model"
or "Reference characteristic", the system checks if the master inspection
characteristic has been completely maintained. The data that you enter depends
on the control indicator settings in the master inspection
characteristic.
- You can reference or copy a "Reference
characteristic".
- You can only copy a "Complete copy
model"
- You can only copy an "Incomplete copy model"
into a task list.
- In this field, the system sets the entry
"Reference characteristic" automatically for master inspection characteristics
that are linked to a class characteristic. You cannot change this
entry.