Displaying Collector Data  

Use

You can use the operating system monitor to display data in the shared memory segment that was collected by the saposcol program.

Prerequisites

saposcol must be running so that the data is available.

Possible Error Messages

Shared memory not available

saposcol has not created a shared memory segment.

This is usually because the saposcol program has not been started.

Collector not running

saposcol was started and created a shared memory segment, but was later terminated.

Data that cannot be collected by saposcol on this platform is labeled N/A ('not available').

Procedure

  1. To call the operating system monitor choose CCMS ® Control/Monitoring ® Performance menu ® Operating system ® Local or Global ® Activity.

To update the screen with the most recent data from the shared memory, choose Refresh. Note that saposcol collects data at 10 second intervals (default). You do not always obtain new data with refresh.

 

See also:

 

Controlling SAPOSCOL from the R/3 System