Indicator you use to specify that a consistency check is automatically carried out before a task list with this status is saved.
The following tables show which checks are carried out for task lists in the individual applications.
If the system finds inconsistencies, you can decide whether you still want to save. The results of the check are documented in a checking log.
You cannot carry out consistency checks for these areas. The indicator is ignored if set here.
| Checked objects | Possible inconsistencies |
|---|---|
| Standard sequence | The validity period of the standard sequence does |
| not agree with the header. | |
| Number of operations | The same number was assigned more than once. |
| and sub-operations | |
| Branch and | The branch operation is greather than the |
| Return operations | return operation. |
| The branch or return operation in a sequence was | |
| deleted. | |
| The smallest operation number in an alternative | |
| sequence is less than the branch operation in the | |
| standard sequence. | |
| The largest operation number in an alternative | |
| sequence is greater than the return operation in | |
| the standard sequence. | |
| Units of measure | The header unit does not agree with the unit of |
| the referenced operation set. | |
| Lot size ranges | The lot size range of an alternative sequence |
| exceeds that of the header. | |
| The lot size range of the header or of an | |
| alternative sequence exceeds that of the referenced | |
| operation set. | |
| Insp.characteristics | The indicator for inspection characteristics |
| is set in the control key of the operation, however, | |
| no inspection characteristics exist for the | |
| operation. |
| Checked objects | Possible inconsistencies |
|---|---|
| Number of | The same number was assigned more than once. |
| operations/phases, | |
| secondary resources, | |
| process instructions and | |
| characteristics | |
| Insp.characteristics | The indicator for inspection characteristics |
| is set in the control key of the operation or phase. | |
| However, no inspection characteristics exist | |
| for the operation or phase. |