Show TOC
Specify System
Reaction to Overlapping Time Infotypes
In this step, you determine how the system
reacts if existing time infotype records overlap with new time infotype
records.
Suchcollision checks are also performed for
subtypes. The concept of a time constraint class was developed so that you do
not have to define a time constraint reaction for each subtype with regard to
all other infotypes or subtypes within an infotype.
Subtypes within an infotype (attendance/absence
type, attendance/absence quota type, availability type and substitution type)
that have the same time constraint reaction are grouped together by the time
constraint class.
Example
In the standard
system, the absence types "sickness with certificate", "cure", and "industrial
accident" are grouped together in time constraint class 01, and the absence
types "leave", "bridge day", and "flextime offset" are grouped together in
time constraint class 02.
The time constraint reaction is determined by a
reaction indicator. The reaction indicator is set for each time constraint
class of an infotype or subtype with regard to the time constraint classes of
all other infotypes or subtypes.
The system can react to a collision in one of
four ways, each of which you can determine using a reaction
indicator.
1.
A: the old record is delimited, ie. the part of the old record
that overlaps with the new record is deleted. One or two new records can be
derived from the old record.
2.
E: the new record cannot be created. The system displays an
error message.
3.
W: the new record can be created without the old record being
changed. The system displays a warning.
4.
N: the new record can be created without the old record being
changed. The system does not display a warning.
Example
1. You want to
prevent the absence types sickness with certificate and
leave from being entered for the same period. To do this,
assign time constraint class 02 to the absence type sickness with
certificate, time constraint class 01 to the absence type
leave and then define time constraint reactions in case these two
time constraint classes collide.
- If a sickness record has already been entered
for the period, you should not be able to enter a leave record. For this
reason, this combination is assigned time constraint reaction E
.
- If a leave record has already been entered for
the period, and you then enter a sickness record, the leave record should be
delimited. For this reason, this combination is assigned time constraint
reaction A. One or two new records are derived from the old
record.
Example:
- old: Jan 02 1997 - Jan 20 1997 paid
leave
- new: Jan 10 1997 - Jan 01 1997 sickness with
certificate
Result: The old
record is delimited and a new leave record is created.
- Jan 02 1997 - Jan 09 1997 paid
leave
- Jan 10 1997 - Jan 12 1997 sickness with
certificate
- Jan 13 1997 - Jan 20 1997 paid
leave
2. A
substitution record is entered for a period for which an absence record
leave already exists. An employee cannot act as a substitute
if he or she is absent, which means that this combination is assigned reaction
indicator E (error message).
3. A
substitution record is entered for a period for which an overtime record
already exists. This combination is allowed; however, the substitution could
give rise to changed working times under certain circumstances. For this
reason, this combination is assigned reaction indicator W
(warning message) to give you an opportunity to recheck your
entries.
4. Anabsence
quota record is entered for a period for which an attendance record already
exists. Attendances and absence quotas are not mutually exclusive. For this
reason, this combination is assigned reaction indicator N
(create without warning message).
Note
When you enter infotype records, the system may
react in a different way to how you specify in Customizing:
1. Special
features for full-day infotype records
2. Special
features for infotype records of less than one day
3. Special
features for infotype records which encompass several days
1. Special features for full-day
records
1. Case 1:
An absence, attendance or
overtime record collides with a substitution which has priority over the
employee's personal work schedule (not a position substitution or a time
substitution combined with a position). The reaction indicator A is defined in
the system settings.
Since the substitution record is taken as the basis for valuating the absence
or overtime, the record cannot be delimited. Instead, the system displays an
error message.
Case 2:
An absence with quota deduction collides with another absence, also with quota
deduction. Both absences are deducted from the same quota. The reaction
indicator A is defined in the system settings for this particular
combination.
Since the first absence with quota deduction (e.g. leave) has already been
deducted from the quota, the system cannot delimit the records. This would
create errors in the quota deduction, so an error message is
displayed.
Case 3:
An absence with quota deduction collides with an absence with quota deduction
which has been maintained manually. It is not possible to delimit the records,
so the system displays an error message.
2. Special features for infotype
records of less than one day
Case 1:
A record of less than one day for which clock times have been entered collides
with a record of less than one day specifying a number of hours only. Reaction
indicators A or E are defined in Customizing for these combinations.
As the system cannot delimit records in this example, or the records do not
collide in certain circumstances, the system displays a warning
message.
1. Case 2:
A record of less than one day specifying clock times or a number of hours
collides with a full-day record or a record which encompasses several days.
Reaction indicator A is defined in Customizing for this combination.
Since the system cannot delimit records in this example, the new record cannot
be created. The system displays an error message.
2. Case 3:
A record of less than one day which specifies a number of hours collides with
a record of less than one day for which a number of hours or clock times have
been entered. Reaction indicators A and E are defined in Customizing.
These records might not overlap depending on the circumstances, so the system
merely displays a warning message rather than delimiting the old record, or
preventing the new record from being created.
Case 4:
Two records collide that both last less than one day and for which clock times
have been entered.
3. If both
records cover the same period, the system reaction depends on the system
settings.
4. If the
periods covered by the records do not overlap, the new record can be created
irrespective of the system settings. The system does not display a warning
message.
5. If the
periods covered by the records overlap, the system reacts as follows:
If the reaction indicator in the system settings is E or W, the system reacts
as specified. If, however, the reaction indicator is A, the system displays an
error message.
3. Special features for records which
encompass several days
If there is a record for the previous day which
extends into the current day (a full-day record or one of less than a day with
clock times), and if there is a record for the current day (a full-day record
or one of less than one day with clock times), the system reacts as
follows:
1. The record
for the previous day overlaps with the current day's record.
The conditions that apply in this case are the ones desribed under special
features for records of less than one day.
2. The record
for the previous day does not overlap with the current day's record.
If you have defined the reaction indicators A and W for this scenarion in the
customizing settings, the system uses reaction indicator W.
Note about the Time Events
infotype
The Time Events infotype (2011) is
available as well, and can be used to set up collision checks. As a rule, it
is not pertinent to check for a collision with time events, as time
evaluations have differing processing possibilities.
Due to consistency reasons, the infotype is in the list; you should leave all
the reaction indicator entries unchanged with the setting N.
Collision checks with the Time Events is no longer
expected.
Requirements
You must define time constraint classes for the
following:
Standard
Settings
The time constraint reaction is already set for
the time constraint classes used by SAP.
Recommendation
Try to make the standard time constraint
classes suffice in your enterprise and to change the reaction indicators
only.
Activities
1. If time
infotypes overlap, check that the system reaction meets your
requirements.
2. If
necessary, change the reaction indicators for a time constraint
class.