Analyzing Plan Reconciliation Results for Activity Input 

  1. Call up the transaction as follows:
  2. Menu Path

    From the Planning Reports node, choose Cost Centers: Planning Overview.

    Transaction Code

    KSBL

  3. Enter the following data:
  4. Field

    Europe

    North America

    Cost center

    4276

    4276

    Fiscal year

    1997

    1997

    Period

    1

    1

    To

    1

    1

    Plan version

    20

    20

  5. Choose Execute.
  6. The system displays the planning values for cost center 4276 (Production) period 1. The current report contains the data as it was before plan reconciliation (plan version 20).

    In the 615000 DIAA Repairs row, you can see activity input from Plant Maintenance cost center 4300. In the Total quantity column, you can see that the input quantity of 500 H is variably planned.

  7. Look at the Plan Reconciliation: List session.
  8. On cost center 4276, the plan activity has been increased from 1000 to 2000 as a result of plan reconciliation. This should mean, however, that the variably planned activity input from cost center 4300 (Plant Maintenance) increases from 500 H to 1000 H.

  9. To determine this, change to the Cost Centers: Planning Report session.
  10. Choose .
  11. Enter the following data:
  12. Field

    Europe

    North America

    Cost center

    4276

    4276

    Fiscal year

    1997

    1997

    Period

    1

    1

    To

    1

    1

    Plan version

    21

    21

  13. Choose Execute.
  14. The system displays the planning report for cost center 4276 after plan reconciliation.

    In the 615000 DIAA Repairs row, you can see that the activity input from Plant Maintenance cost center 4300 has indeed been increased from 500 H in basic plan variant 20 to 1000 H.

  15. Switch to the Plan Reconciliation: List session.
  16. Select cost center 1230, then choose Activity analysis.
  17. To expand the tree structure, choose +.

The following information is displayed:

  1. Choose .
  2. You can see that cost center 1230 (Energy) also had to increase the plan activity from 1000 to 1250 due to the higher energy consumption by the Plant Maintenance cost center.

  3. Switch to the Cost Centers: Planning Report session.
  4. Select 4300 (Plant Maintenance) in the Partner object column, then choose .
  5. This brings you from the planning report for Production cost center 4276 to the planning report for Plant Maintenance cost center 4300.

    In the 617000 DIAA Energy row, you can see an activity input from cost center 1230 (Energy) with the input quantity of 500 H fixed, and 750 H variable (as previously seen in the activity reconciliation tree for the plan reconciliation).

  6. Select 1230 (Energy) in the Partner object column, then choose .
  7. Remain on this screen.