Adding Activities and System Availability to Malfunction Report 

Use

Based on your investigation, you assign to the notification the maintenance measures required for solving the problem.

Procedure

  1. Choose to process the malfunction report.
  2. Enter the following data:
  3. Field

    Europe

    North America

    Description

    Short text

    Defect electric pump 001

    Defect electric pump 001

     

    Equipment

    P-1000-N003

    P-3000-N003

    Electric pump 003

  4. Position your cursor on the Object part field and choose F4 help.
  5. Expand the PUMP/100 – Pump components hierarchy and choose 1001 – Inlet/Outlet.
  6. Choose the Activities tab page.
  7. Position your cursor on the first line of the Code group column, then choose F4 help.
  8. Expand the hierarchy Pump/101 – Plant maintenance activities pumps and choose activity 2007, Change Seals.
  9. Choose the System availability tab.
  10. Enter the following data:
  11. Field

    Data

    Description

    Effect

    2

    Production restriction

    Avail. before malfunction

    100

    Percent

    Cond. before malfunction

    1

    Operational

    AvailAftMalfunction

    60

    Percent

    CondAftMalfunction

    2

    Restricted operation

  12. Choose .
  13. Choose to return to the order.
  14. Do not leave this screen.