Example of Results Confirmation 

For the inspection characteristic with the confirmation number 00000007, the measured values of 10 inspected single units are to be confirmed. The characteristic specification record transferred to the subsystem contains the following data:

Field

Content

ERFASSART

A

KZPRUMF

=

SOLLSTPUMF

0000010

KZSERNR

X

 

If processing of the inspection characteristic is to be completed successfully in QM, 10 single-result records with the QAISE structure and the record type Q51 must be created for the inspection characteristic. The following required fields must be filled:

Field

Content

SATZART

Q51

RUECKMELNR

00000007

PROBENR

000000

KZSERNR

X

SERIALNR

XYZ1000000000-4711

MESSWERT

0000000000123.45