Results Confirmation for Single Results Using Record Types Q51, Q52, Q53, Q54, Q55, Q56, and Q58: Function Module QIRF_GET_ORIGINAL_VALUES2 

Use

Parameters of Function Module QIRF_GET_ORIGINAL_VALUES2

® Input

– Indicator: Transfer valuations from subsystem, I_IND_EVALUATION_TRANSFER

 

– Indicator: Close samples or characteristics, I_IND_CLOSE_PROCESSING

 

– Table of single results (structure QAISE), T_QAISETAB

 

– Indicator: Send error log by mail, I_SEND_PROTOCOL_MAIL

 

– Subsystem confirms results, I_SUBSYS

 

– Indicator: Call up program for updating results, I_IND_POSTING_KZ

 

– Indicator.: Trigger commit work to database, I_IND_PROC_COMMIT_WORK

¬ Output

– Error log list (structure QIERR), T_QIERRTAB

 

If the indicator Transfer of valuations from subsystem is set, the valuation and defect class for the single results are transferred from the subsystem to the QM component. If a single result to be transferred is marked as the last single value (field KZLWERT) and partial samples are to be taken for a characteristic, the data in the MBEWERTGPR and FEHLKLASPR fields (valuation and defect class for sample) is transferred. If only the result of a single sample is requested for a characteristic, the valuation and defect class are transferred in the MBEWERTGMK and FEHLKLASMK fields (valuation and defect class for characteristic).

If characteristics or samples are to be closed (Close samples or characteristics indicator), and a single result record is marked as the last single value, either the sample or the characteristic is closed depending on whether partial samples are to be taken for the characteristic or not.

When closing characteristics requiring documentation (QAIMV-KZDOKU) an inspection description must be confirmed at characteristic level. These characteristics cannot be closed using function module QIRF_GET_ORIGINAL_VALUES2. In this case, the characteristics are closed using record type Q79 and function module QIRF_GET_FEATURE_VALUES2.

If the indicator Transfer of valuation from subsystem is not set, the characteristics are valuated in the QM component.

If the ERFASSART field has value J, K, L, M, N, or O, the sample number must be entered.

See also:
Graphic
Function Module QIRF_GET_ORIGINAL_VALUES2