Messages from BR182E to BR218E 

BR182E Checking parameter/option %s failed

BR183E Values '%s' of option '%s' not ascending

BR184E Maximal %d values can be defined for parameter %s

BR185E File %s defined in IFILE parameter not in %s

BR186E Compress directories %s and %s on the same disk volume

BR187E Value %d of parameter/option %s smaller than %d

BR188E Value %d of parameter/option %s greater than %d

BR189W Expiration period equals 0 – backup volumes could be immediately overwritten

BR190E Parameter %s in form \\.\tapex not supported any more – please use %s instead

BR191E Value '%s' of parameter/option '%s' not supported for '%s'

BR192E cpio block size in option - C is not a multiple of 512

BR193I,W,E Files to be backed up are already compressed

BR194I,W,E First offline redo log file %s to be backed up, which was found in line %d of %s, is already compressed

BR195I Compressed files cannot be verified using DB_VERIFY

BR196I Original file %s was a file on raw device – its copy on disk cannot be saved by backup utility

BR197I Chained start not supported for '%s'

BR198I Profiles successfully saved

BR199I Volume label(s) successfully checked

BR201I Compressing %s

BR202I Saving %s

BR203I to %s...

BR204I Percentage done: %3.2f%%, estimated end time: %02d:%02d

BR205I Backup volume initialization

BR206I End of backup volume initialization

BR207I Volumes in devices: %s will be initialized with names: %s

BR208I Volume with name %s required in device %s

BR209I Volume in device %s has name %s

BR210I Please mount the volumes, if you have not already done so

BR211W Unattended mode impossible - volume remount required
BR211E Unattended mode impossible - volume remount required

BR212I Please check the volume or the device

BR213W Rewind of volume in device %s failed
BR213E Winding tape volume in device %s failed

BR214W Label on volume in device %s not found
BR214E Label on volume in device %s not found

Case 2: If this error occurs at the end of a backup, this means that the backup to that volume was not successful.

Fall 2: Check whether the parameters tape_address ( no-rewind address) and tape_address_rew ( rewind address) are defined correctly. Make sure than no other processes access the backup device during the backup. Correct the contents of the volume if necessary and repeat the operation.

BR215W Label on volume in device %s has wrong format
BR215E Label on volume in device %s has wrong format

BR216W Wrong volume %s found in device %s, expected: %s BR216E Wrong volume %s found in device %s, expected %s %s

BR217W Lock period for volume %s in device %s not expired
BR217E Lock period for volume %s in device %s not expired

BR218W Checking label on volume in device %s failed
BR218E Reading volume label from %s failed