Integrity Check for Batch Classification 
Use
The field CUOBJ_BM in the batch master record table contains the internal number that is used to store classification data for an object (batch). This number can be used to determine the class that is assigned to the batch and the characteristic value assignment.
You use this function to:
Integration
The redundant storage of internal numbers in the batch master record table increases performance in the Batch Determination function.
Features
Selection Criteria
You can select batches for an integrity check according to the following criteria:
You can select batches by plant only if the batch level has been set to plant level in your system.
Test Run
To find out in advance about the check status of the batches selected, you can carry out a test run of the integrity check. During the test run, the system does not make changes to data. It does not fill the field CUOBJ_BM in the batch master record table and cannot repair the batch classification.
Check Status
Classification consistent - CUOBJ copied
The classification table INOB contains one table record for the object (batch), the key of which can be copied to the field CUOBJ_BM (test run) / has been copied to the field CUOBJ_BM (update run).
Non-Classified Batches
The classification table does not contain an INOB record. The field CUOBJ_BM is blank in the batch master record table.
Consistent Batch Classification
The classification table contains one record. The field CUOBJ_BM is already filled.
Batch Has CUOBJ_BM – INOB Is Missing
The classification table INOB does not contain a record for the batch. But the table KSSK does contain a record. The missing INOB entry is created when the batch classification is being repaired.
Batch Has CUOBJ_BM – INOB and KSSK Are Missing
The field CUOBJ_BM is filled in the batch master record table. There are no entries in the tables INOB and KSSK. But there are AUSP entries. When the batch classification is being repaired, the entries are created for the tables INOB and KSSK.
Batch Has Incorrect CUOBJ_BM
The system found one INOB record, the key of which is different from the contents of the field CUOBJ_BM. The entry in the batch master record table is updated in accordance with the entry in the classification table.
Non-Classified Batch with CUOBJ_BM
There are no INOB, KSSK, or AUSP entries. The CUOBJ_BM entry is deleted when the batch classification is repaired.
Several INOB Entries Exist
The system found several INOB records for the batch. It tries to delete the incorrect records. If the INOB record does not contain KSSK or AUSP entries, the system deletes it. If only one INOB record remains, the system copies the key for this record to the field CUOBJ_BM. If there is more than one INOB record, the system cannot complete the repair successfully.
Error Corrected Successfully
The repair was carried out successfully.
Errors that Cannot Be Corrected
The errors that occurred cannot be corrected with this function.
Error During DB Update
The error cannot be corrected because the batch is blocked; that is, it is currently being processed.
Dummy Batch with MCHA - Entry
When materials are valuated separately at plant level, the system creates an entry in the batch master record table MCHA. In this case, the field CUOBJ_BM is not filled.
Dummy Batch with CUOBJ_BM
The field CUOBJ_BM is filled although the entry in the batch master record table is based on split material valuation. The CUOBJ_BM entry is deleted when the batch classification is repaired.
Activities
.If a repair is required, the system displays the
pushbutton.
to carry out the repair.