Performing the Inspection 

  1. Call up the transaction as follows:
  2. Menu Path

    From the Quality Inspection node, choose Inspection Result ® For Operation ® Record

    Transaction Code

    QE01

    Results Recording for Operation 0010 Visual Inspection

  3. Enter the following data:
  4. Field

    Data

    Inspection lot

    Your number (default)

    Operation

    10 Visual inspection

    Char. filter

    All characteristics

    Inspector

    Your name (default)

    Insp.start time

    Current time (default)

  5. Choose .
  6. You now see a list of inspection characteristics for the visual inspection. In the Status column, you can see the processing status (possible entries help).

  7. To select all characteristics, choose .

Damage to Packaging

  1. Double-click on the characteristic Damage to packaging.
  2. The detail screen appears. You can see that all 10 packages need to be inspected.

  3. Enter the following data:
  4. Field

    Data

    Nonconf.

    1

  5. Choose .
  6. In the dialog box, enter "Viewing window damaged" and choose .

 (Valuation: rejected) appears in the upper screen area.

The system automatically rejected and closed the characteristic due to the number of nonconforming units.

Missing Quantity

  1. To call up the entry screen for the characteristic Missing quantity, choose (Next char.).
  2. To generate a description of the inspection method, choose Insp.method.
  3. In the dialog box, you see a description of the inspection method.

  4. Choose Continue.
  5. In the Results screen area, enter the following data:
  6. Field

    Data

    Nonconf.

    1 (1 package contains too few screws)

    No. defs

    1 (1 screw less in the package)

  7. Choose .
  8. In the dialog box, you see that an automatic valuation is not possible due to the current sampling plan and number of defects. A double sample is planned for this inspection characteristic.

  9. In the dialog box, choose (Extend sample).
  10. You can see that the inspection scope has increased from 1 to 2. There is no screw missing from the second package.

  11. Enter the defect number 1 (new entry) and choose .

The valuation icon appears in the upper screen area.

The system automatically accepted and closed the characteristic due to the number of defects.

ID of Property Class

  1. To call up the entry screen for the characteristic ID of property class (strength), choose .
  2. To view the ID that meets the standard, choose in the Test Eqpmt line.
  3. A drawing of the screw head is displayed.

  4. Exit this screen.
  5. In the Code field of the Results screen area, choose the possible entries help. In the Catalog selection dialog box that appears, choose code 001On top of screw head.
  6. Choose .

The valuation icon appears in the upper screen area.

The system automatically valuates the characteristic on the basis of the code and closes the process.

Electroplating

  1. To call up the entry screen for Electroplating, choose .
  2. Enter the following data:
  3. Field

    Data

    Class 3 Dull finish, yellowish brown

    9

    Class 7 Bright, yellowish brown

    1

  4. Choose .
  5. On the basis of this qualitative classification, the system accepts the characteristic and closes the process.

  6. Choose .

The initial screen for results recording appears.

Results Recording for Operation 0020 Mechanical Inspection

  1. Enter the following data:
  2. Field

    Data

    Inspection lot

    Defaulted

    Operation

    20 Mechanical insp.

    Characteristic filter

    All characteristics (possible entries help)

    Inspector

    Default

    Insp.start time

    Current time (default)

  3. Choose .
  4. You now see a list of inspection characteristics for the mechanical inspection. In the Status column, you can see the processing status (possible entries help).

  5. To select all characteristics, choose .

Thread Length L

  1. Choose the line with characteristic thread length l and double-click on the inspection characteristic short text.
  2. The detail screen appears. Five screws need to be inspected individually.

  3. Enter the following measured values:
  4. Field

    Data

    No.1

    20.2

    No.2

    19.9

    No.3

    19.7

    No.4

    20.0

    No.5

    18.9

  5. Choose .

One of the measured values lies outside the tolerance value, so the system rejects the characteristic and closes the operation.

Brinell Hardness

  1. To call up the entry screen for the characteristic Brinell hardness, choose .
  2. Five screws need to be inspected.

  3. Enter the following data:
  4. Field

    Data

    Class 4

    1

    Class 5

    3

    Class 6

    1

  5. Choose .
  6. The system closes and accepts the characteristic.

  7. Choose Histogram.
  8. The distribution frequency of the classes is displayed.

  9. To close the screen with the histogram, choose ® Close window in the lower screen area.
  10. Choose Control chart.
  11. The control chart for brinell hardness is displayed.

  12. To close the screen with the control chart, choose ® Close window in the lower screen area.
  13. Choose .

Service Entry Sheet

  1. Enter the following data:
  2. Field

    Data

    Setup

    0.5 (default)

    Machine

    0.1

    Labor

    0.2

    The working hours used to perform the mechanical inspection are entered.

  3. Choose .
  4. The system calculates the appraisal costs and saves the inspection results.

  5. Choose until the overview tree appears.