Checking the Forecast Result in Online Mode 
Errors or exceptional situations which appear during the total forecast are recorded in the exception messages and are allocated to a certain error class. If an error occurs in a material forecast, then the system marks the material for which the error occurs for reprocessing.
If you want to check the forecast result in online mode and reprocess the marked materials, proceed as follows:
The initial screen for Forecast Reprocessing appears.
If you want to limit the selection to a certain interval, you must enter the appropriate period indicator.
Furthermore, you can limit the selection of exception messages to one particular error class by selecting various error classes. The following Table shows which types of exception messages exist and to which error class they are allocated.
Description of error classes
Exception message |
Error class |
Reorder level and safety stock |
1 |
Model selection and test |
2 |
Initialization |
3 |
Parameter optimization |
4 |
Difficulties during the forecast |
5 |
Forecast not calculated |
6 |
Missing table entries |
7 |
Terminations |
8 |
A list of materials now appears displaying those materials for which one or more forecast errors occurred and which correspond to your selection.
The Parameter Overview for the selected material now appears.
A screen with the corresponding exception message appears. You can now see what caused the error during the forecast.
Example:
The MRP controller did not enter any historical values when creating the material master record. You must now respond to this situation with manual initialization.
The system carries out the forecast and displays the forecast value with the message:
Forecast calculation was carried out.
The forecast values were saved.
By saving the new forecast result, the system then records that the material in question has been reprocessed and this material will automatically be deleted from the list of materials to be reprocessed.